Index
Sub-
index
Name
Length
Value Range
Default
Access
Rights
Data
Storage?
Smart Sensor
Profile?
AOI
23
Firmware Version
ro
y
24
App Specific Tag (user
defined)
rw
y
y
25–35
reserved
36
Device Status
8-bit integer
0 = Device is OK
1 = Maintenance required
2 = Out of specification
3 = Functional check
4 = Failure
5..255 Reserved
ro
37
Detailed Device Status
Array[6] of 3-octet
ro
38–39
reserved
40
Process Data Input
ro
41
Process Data Output
42–57
unused/reserved
58
Teach-in Channel
0= Default
1 = BDC1
2 = BDC2
0
rw
y
59
Teach-In Status
59
1
Teach State: 4-bit Integer
4-bit Integer
0 = Idle
1 = SP1 Success
4 = Wait for Command
5 = Busy
7 = Error
ro
y
59
2
SP1 TP1
1-bit integer
0 = not taught or unsuccessful
1 = successfully taught
ro
y
59
3
SP1 TP2
1-bit integer
0 = not taught or unsuccessful
1 = successfully taught
ro
y
60
BDC1 Setpoints
60
1
BDC1 Setpoint SP1
32-bit integer
95 mm – 2000 mm
250 mm
rw
y
y
60
2
BDC1 Setpoint SP2
32-bit integer
0 mm for all teach modes except
One-Point Window (FGS)
95 mm to 2000 mm for One-Point
Window (FGS)
0 mm
rw
y
y
61
BDC1 Configuration
61
1
BDC1 Switchpoint Logic
8-bit integer
0 = LO
1 = DO
0
rw
y
y
61
2
BDC1 Mode
8-bit integer
1 = One-Point BGS
128 = Two-Point Static BGS
129 = Dynamic BGS
130 = One-Point Window (FGS)
131 = Dual Teach
128
rw
y
y
61
3
BDC1 Hysteresis
16-bit integer
0 mm – 2000 mm
0
rw
y
y
62
BDC2 Setpoints
62
1
BDC2 Setpoint SP1
32-bit integer
95 mm – 2000 mm
500 mm
rw
y
y
62
2
BDC2 Setpoint SP2
32-bit integer
0 mm for all teach modes except
One-Point Window (FGS)
95 mm to 2000 mm for One-Point
Window (FGS)
0 mm
rw
y
y
63
BDC2 Configuration
63
1
BDC2 Switchpoint Logic
8-bit integer
0 = LO
1 = DO
0
rw
y
y
IO-Link Data Reference Guide: Q5X Sensor