Octet 3
Subindex
4
4
4
4
4
3
2
1
Bit offset
7
6
5
4
3
2
1
0
Value
1
1
1
1
1
1
0
1
Example Based on the Value Above
Channel 1 Output = Active
Channel 2 Output = Inactive
Stability State = Stable
Measurement 1 Value = 8191
Measurement 2 Value = 694
Process Data (If Binary Data Is Not Included)
Process Data Input
Subindex
Name
Number of Bits
Data Values
1
Measurement 1 Value
16
Value depends on "Configuration.Measurement 1
Selection"
2
Measurement 2 Value
16
Value depends on "Configuration.Measurement 2
Selection"
Octet 0
Subindex
2
2
2
2
2
2
2
2
Bit offset
31
30
29
28
27
26
25
24
Value
0
0
0
0
0
0
1
1
Octet 1
Subindex
2
2
2
2
2
1
1
1
Bit offset
23
22
21
20
19
18
17
16
Value
0
1
0
0
1
0
1
1
Octet 2
Subindex
1
1
1
1
1
1
1
1
Bit offset
15
14
13
12
11
10
9
8
Value
0
1
1
0
0
1
1
1
Octet 3
Subindex
1
1
1
1
1
1
1
1
Bit offset
7
6
5
4
3
2
1
0
Value
1
0
0
0
1
1
1
1
Example Based on the Value Above
Measurement 1 Value = 26511
Measurement 2 Value = 843
IO-Link Process Data Out (Master to Device)
Process Data Output
Subindex
Name
Number of Bits
Data Values
1
Transducer Disable
1
0 = Active
1 = Inactive
IO-Link Data Reference Guide: Q5X Sensor
2
www.bannerengineering.com - Tel: + 1 888 373 6767
P/N 206834 Rev. B