IO-Link Data Map
This document refers to the following IODD file: Banner_Engineering-Q5X-20180313-IODD1.1.xml. The IODD file and support files
can be found on
www.bannerengineering.com
, under the download section of the product family page.
Communication Parameters
The following communication parameters are used.
Parameter
Value
IO-Link revision
V1.1
Process Data In length
32 bits
Process Data Out length
8 bits
Bit Rate
38400 bps
Minimum cycle time
3.6 ms
Parameter
Value
Port class
A
SIO mode
Yes
Smart sensor profile
Yes
Block parameterization
Yes
Data Storage
Yes
IO-Link Process Data In (Device to Master)
Process Data In is transmitted cyclically to the IO-Link master from the IO-Link device.
Process Data (If Binary Data Is Included)
Process Data Input
Subindex
Name
Number of Bits
Data Values
1
Channel 1 Output State
1
0 = inactive
1 = active
2
Channel 2 Output State
1
0 = inactive
1=active
3
Stability State
1
0 = no target/marginal
1 = stable
4
Measurement 1 Value
13
Value depends on "Configuration.Measurement 1
Selection"
5
Measurement 2 Value
16
Value depends on "Configuration.Measurement 2
Selection"
Octet 0
Subindex
5
5
5
5
5
5
5
5
Bit offset
31
30
29
28
27
26
25
24
Value
0
0
0
0
0
0
1
0
Octet 1
Subindex
5
5
4
4
4
4
4
4
Bit offset
23
22
21
20
19
18
17
16
Value
1
0
1
1
0
1
1
0
Octet 2
Subindex
4
4
4
4
4
4
4
4
Bit offset
15
14
13
12
11
10
9
8
Value
1
1
1
1
1
1
1
1
IO-Link Data Reference Guide: Q5X Sensor
Original Document
206834 Rev. B
7 February 2019
206834