![Banner LTF Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/banner/ltf/ltf_instruction-manual_3831760015.webp)
June 22, 2023
LTF Time Of Flight Laser Distance Sensor Instruction Manual
15
Remote Input Map
5x
6x
4x
3x
2x
1x
Set Window Size to X1 , then back to Run mode
Set Window Size to X2 , then back to Run mode
Set Window Size to X3 , then back to Run mode
Set Window Size to X4 , then back to Run mode
Set Window Size to X5 , then back to Run mode
Set Window Size to X6 , then back to Run mode
1x
2x
1x
1x
2x
1x
Select Slope Positive, then back to Run mode
Select Slope Negative, then back to Run mode
8x
Enter Remote TEACH RMT TCH with measurement value
Enter Remote Setup REMOTE SETUP
Teaching..(4mA)
Tch4mA with measurement value, then to Tch20mA
Teaching..(20mA)
Tch20mA with measurement value, then back to Run mode
1x
REMOTE TEACH
REMOTE SETUP
Slope
Slope value (positive or negative)
Window Size
WndSize with value
Sensor Lock / Unlock
Locks or Unlocks Sensor
Lock Sensor
Unlock Sensor
Reset to Default Settings Resets Sensor to Factory Default Settings
0.04 seconds < T < 0.8 seconds
Timing between Pulse groups > 1 second
Pulse Timing (T)
NOTE: Follow procedure for the TEACH/SET method
(highlighted in black box) chosen in the TEACH Selection menu.
Timeout is 60 seconds.
3x
2x
Teaching.. (SPt1)
TchSPt1 with measurement value, then to TchSPt2
Teaching..(SPt2)
TchSPt2 with measurement value, then back to Run mode
1x
3x
Teaching.. (TchA&D1)
Tch4mA and TchSPt1 with measurement value, then to TchA&D2
Teaching..(TchA&D2)
Tch20mA and TchSPt2 with measurement value, then
1x
4x
Teaching.. (Tch12mA)
Tch12mA with measurement value, then back to Run mode
5x
Teaching.. (TchMdPt)
TchMdPt (teaches SPt in Switch Mode) with measurement value, then
6x
Teaching.. (TchA&D)
Tch12mA and TchMdPt (teaches SPt in Switch Mode) with measurement
value, then back to Run mode
5x
6x
4x
3x
2x
1x
Set Mode to Alarm, then back to Run mode
Set Mode to Health, then back to Run mode
Set Mode to Switch , then back to Run mode
Set Mode to Switch , then back to Run mode
Set Mode to Window , then back to Run mode
Set Mode to Window , then back to Run mode
Sensor Mode
Mode with current value
2x
Run
Mode
2x
1x
4x
back to Run mode
back to Run mode
Refer to the Window size table for the acceptable values.
© Banner Engineering Corp.
Содержание LTF
Страница 4: ...Blank page 4...
Страница 12: ...Blank page 12...
Страница 44: ...Blank page 44...
Страница 52: ...Blank page 52...
Страница 58: ...Blank page 58...
Страница 60: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...