4 Specifications
4.1 General Specifications
Supply Current (mA)
Emitter
Receiver*
Standard
Length
Max**
Typical
Max**
Typical
350
30
25
115
72
420
30
25
117
74
630
30
25
124
80
910
31
26
134
89
1050
31
26
139
93
1190
31
26
144
97
1260
32
26
146
99
1330
32
26
149
101
1540
32
27
156
108
1820
32
27
166
116
* Supply current exclusive of OSSD1 and OSSD2 loads (up to additional 0.5 A each) and Fault Output load (up to 0.070 A).
** Maximum current occurs at a supply voltage of 20 V DC.
Supply Voltage at the Device
24 V DC ±15% (use a SELV-rated power supply according to EN IEC
60950).
The external voltage supply must be capable of buffering brief mains
interruptions of 20 ms, as specified in IEC/EN 60204-1.
Residual Ripple
±10% maximum
Short Circuit Protection
All inputs and outputs are protected from short circuits to +24 V DC or
DC common
Resolution
23 mm, depending on the model
Effective Aperture Angle (EAA)
Meets Type 4 requirements per IEC 61496-2
Enclosure
Extruded aluminum housing with black anodized finish (previous units
had a yellow polyester powder finish) standard and well-sealed, rugged
die-cast zinc end caps, acrylic lens cover
Electrical Safety Class
III (per IEC 61140: 1997)
Environmental Rating
IP65/IP67
Operating Conditions
–20 °C to +55 °C (–4 °F to +131°F)
95% maximum relative humidity (non-condensing)
Mounting Hardware
All mounting hardware is ordered separately. Models longer than 910
mm should use an additional center-mount bracket for support. Mounting
brackets are 8-gauge cold-rolled steel, black zinc finish.
Cables and Connections
on page 62
Safety Rating
Type 4 per IEC 61496-1, -2
Category 4 PL e per EN ISO13849-1
SIL3 per IEC 61508; SIL CL3 per IEC 62061
PFHd: 1.30 × 10
-10
Proof Test Interval: 20 years
Operating Range
0.1m to 8 m (4 in. to 26.2 ft) — Range decreases with use of mirrors
and/or lens shields:
•
Lens shields — approx 10% less range per shield
•
Glass-surface mirrors — approx 8% less range per mirror
See the specific mirror datasheet for more information.
Shock and Vibration
Components have passed vibration and shock tests according to IEC
61496-1. This includes vibration (10 cycles) of 10-55 Hz at 0.35 mm
(0.014 in) single amplitude (0.70 mm peak-to-peak) and shock of 10 g
for 16 milliseconds (6,000 cycles).
Certifications
Banner Engineering
Europe
Park Lane,
Culliganlaan 2F bus 3,
1831 Diegem, BELGIUM
Turck Banner LTD
Blenheim House,
Blenheim Court, Wickford,
Essex SS11 8YT, Great
Britain