Output 1 and Output 2
The sensor has two output signals that you can configure for Pass, Fail, Read, No Read, Match, No Match, System Error,
and Missed Trigger. The default settings are Pass for Output 1, Fail for Output 2.
NOTE: For all outputs, the default setting is Latched, which means that the signal is active until the
results of an inspection cause a change in the signal output. If Pulsed is selected, the default pulse
width is 50 ms.
Serial Output
The iVu BCR has an RS-232 serial communications port that is used to output barcode data to other applications. The user
can enable or disable serial output. When enabled:
•
if the sensor is configured for either External-Single or External-Gated trigger modes, every trigger results in the
transmission of output data (if the sensor does not successfully read a barcode, the output will be NO_READ).
•
if the sensor is configured for Continuous trigger mode, the sensor will only transmit output barcode data upon a
successful read.
Additionally, when serial output is enabled, the user can configure:
•
serial port settings including --
◦
Baud rates
◦
Start bits
◦
Stop bits
◦
Data bits
◦
Parity control
•
the data to export, including any or all of the
following—
◦
Pass/Fail Output
◦
Symbol Type
◦
Barcode Data Length
◦
Barcode data
•
Output Format, including—
◦
Start String
◦
Delimiter
◦
End String
Main Menu
The Main Menu has four sections:
•
Inspection—to modify inspection settings
•
Imager—to run the Auto Exposure routine and to make
adjustments to functions like exposure, gain, and strobe
•
System—to set output signals, communication channel
parameters and to manage the device
•
Logs—to configure and view System and Inspection Logs