Installing and Connecting the Sensor
The iVu BCR sensor requires a bracket for mounting. Three brackets are available from Banner. The brackets allow the
sensor to be mounted either perpendicular to the part or at an adjustable angle.
Thread three M4 x 4mm screws through the bracket into the mounting holes in the bottom of the sensor. Tighten all three
screws.
Table 1: iVu Brackets
SMBIVURAL
SMBIVURAR
SMBIVUU
Cable Connections for iVu BCR with Integrated Display
The cable connections on the iVu BCR sensor are shown below, and the power I/O connections (B) are defined in
on page 2.
A
USB Connector
B
Power I/O Connector
NOTE: Micro video lens model shown. C-Mount model
connections are identical.
Table 2: Power I/O Connections
Pin #
Wire Color
Description
Direction
1
White
Output 1
Output
2
Brown
10-30V dc
Input
3
Green
Output 2
Output
4
Yellow
Strobe Out (5V dc only)
Output
5
Gray
Remote Teach
Input
6
Pink
External Trigger
Input
7
Blue
Common (Signal Ground)
Input
8
Red
Ready
Output
9
Orange
Not used
N/A
10
Light Blue
RS-232 TX
Output
11
Black
RS-232 Signal Ground
Output
12
Violet
RS-232 Rx
Input
Cable Connections for the iVu BCR with a Remote Display
The cable connections on the iVu BCR sensor are shown below, and power I/O connections (B) are defined in
on
page 3.
iVu BCR Gen2 Series Sensor
2
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 178445 Rev. A