Method
Action
Result
SET Button
Present ON and OFF conditions
Display: Red - Signal Level; Green -
Threshold
Remote Input
Present ON and OFF conditions
4. Exit Dynamic TEACH.
Method
Action
Result
SET Button
Click the SET rocker button
TEACH Accepted
Displays alternate "PASS" with %
Minimum Difference10, Sensor returns
to Adjust mode
TEACH Not Accepted
Displays alternate "FAIL" with %
Minimum Difference10, Sensor returns
to Adjust mode
Remote Input
Single-pulse remote input
T
5. Return to RUN Mode.
Method
Action
Result
SET Button
Move Mode switch to RUN
Display: Red - Signal Level; Green -
Threshold
Remote Input
No action required; sensor returns to
RUN mode automatically
Window SET
• Sets window thresholds that extend a programmable % offset above and below the presented condition
• All other conditions (lighter or darker) cause the output to change state
• Sensing window center can be adjusted using "+" and "-" rocker button (Manual Adjust)
• Recommended for applications where a product may not always appear in the same place, or when other signals
may appear
• See Program Mode for programming the Offset Percent setting
A single sensing condition is presented, and the sensor positions window thresholds a programmable % offset above and
below the presented condition. In LO mode, Window SET designates a sensing window with the Output ON condition inside
the window, and the Output OFF conditions outside the window.
Sensor positions
window thresholds
a programmable %
offset from the
presented condition
Darkest
(no signal)
Most Light
(saturated
signal)
Condition
Presented
Sensing Window
Output OFF
Output OFF
Output ON
Figure 10. Window SET (Light Operate shown)
10 See
on page 22 for more explanation of the % Minimum Difference displayed after the Dynamic TEACH
method.
DF-G3 Long Range Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link
16