3.3 Remote Input
Use the input wire to program the sensor remotely. To program the sensor using the input wire, remote input must be
enabled (inPT SEL = SEt). The remote input provides limited programming options (see the figure below). Pulse the remote
input according to the figures and the instructions provided in this manual.
Note: For NPN models, the remote input pulses are active low as shown in the following figures. For PNP
models, the remote input pulses are active high and are inverted from the following figures.
Remote
Input
1x
1x
3x
2x
1x
One-Point Window
4x
One-Point Light Set
6x
CAL Set
5x
One-Point Dark Set
Two-Point
Dynamic
Remote Setup
REMOTE TEACH
REMOTE SETUP
Teach Selection
1x
Completes Teach
Starts Selected Teach
0.04 seconds < T < 0.8 seconds
Timing between Pulse groups > 1 second
Pulse Timing (T)
NOTE: Follow procedure for the selected TEACH/SET method
(highlighted in black box) chosen in the TEACH Selection menu
3x
2x
1x
LO
DO
LO/DO Selection
2x
2x
1x
Button Unlock (uloc)
Button Lock (loc)
4x
Button Lock (loc) or Unlock (uloc)
8x
Factory Default Settings
Figure 7. Single Output — Remote Input Flowchart
3.4 Sync Master/Slave
Up to seven DF-G3 sensors may be used together in a single sensing application. To eliminate crosstalk between the
sensors, configure one sensor to be the master and the remaining sensors to be the slaves. In this mode, the sensors
alternate taking measurements and the response speed is 2 ms.
Note: Note: In this mode, all sensors must either be NPN or PNP output models.
1. Configure the first sensor as the Master (inPt SEL = MAST).
2. In the Master sensor set-up, enter the total number of Slave sensors you will be using (tOtL SLAV = 1 - 6).
3. For each Slave sensor used, configure the input as a Slave (inPt SEL = SLVE).
4. Give each Slave its own identifying address (SLAV Addr = 1 - 6).
5. Connect the Input wires of the Master and all of the Slaves together.
Note: Note: Giving two Slave sensors the same address will cause them to fire their emitters at the same
time in the firing sequence.
3.5 Adjust Mode
Sliding the RUN/PRG/ADJ mode switch to the ADJ position allows the user to perform Expert TEACH/SET methods and
Manual Adjustment of the threshold(s).
DF-G3 Long Range Expert Dual Display Fiber Amplifier with Dual Discrete Outputs and IO Link
12