Method
Action
Result
Push Button
Press and hold the Static (-) button > 2 seconds
•
Display flashes “1St”
•
Arrow icon turns red
Remote Input5
Single-pulse the remote line
T
•
Display flashes “2nd”
•
Arrow icon turns red
2. SET the Output OFF condition.
Method
Action
Result
Push Button
a. Present the Output OFF condition
b. Four-click the Static button
Threshold condition accepted
•
Display flashes “Sn6l,” then "Lt"
twice
•
Sensor returns to RUN mode with
new settings
•
Arrow icon turns green
Threshold conditions unacceptable
•
Display flashes “FAIL” and
returns to “1St”
•
Arrow icon remains red
•
After 60 seconds, the sensor
returns to RUN mode (the Arrow
icon turns green) without
changing settings
Remote Input
a. Present the Output OFF condition
b. Four-pulse the remote line
T
T
T
T
T
T
T
Single-Point Dark Set - Discrete Only
• Sets a threshold slightly above the taught condition
• Any condition lighter than the threshold condition causes the output to
change state
• Threshold position is adjustable using the “+” and “-” buttons (see
on page 9)
• Recommended for applications where only one condition is known, for
example a stable dark background with varying lighter targets
A single sensing condition is presented, and the sensor positions a threshold
slightly above the taught condition. When a condition lighter than the threshold is
sensed, the output either turns ON or OFF, depending on the Light/Dark Operate
setting (see
on page 10).
Threshold position
adjusted by
Manual Adjust
Sensor positions
threshold slightly above
the presented condition
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF
Output ON
Condition
Presented
Figure 11. Single-Point Dark Set (Light Operate shown)
Dark Set and Light/Dark Operate Selection
Dark Set teaches the Output OFF condition and forces the sensor into Light Operate (LO) mode. The sensor can be reconfigured to Dark
Operate (DO) mode after the condition has been taught (see
on page 10).
5 0.04 seconds
≤
T
≤
0.8 seconds
D10 Expert
™
- Analog and Discrete Outputs
8
www.bannerengineering.com - Tel: +1-763-544-3164
P/N 65448 Rev. G