Two-Point Static TEACH (Threshold)
•
Establishes a single switching threshold
•
Threshold position is adjustable using “+” and “-” buttons (see
Manual Adjust)
Static TEACH is the traditional setup method, used when two
conditions can be presented by the user. The sensor locates a single
sensing threshold (the switchpoint) midway between the two taught
conditions, with the Output ON condition on one side, and the Output
OFF condition on the other.
The first condition taught is the ON condition. The Output ON and OFF
conditions can be reversed by changing Light/Dark Operate status in
Setup mode (see
on page 8 ).
Static TEACH and Manual Adjust. Using Manual Adjust with Static
TEACH moves the switching threshold. The lighted LED on the bar
graph will move to exhibit the received signal, relative to the
switchpoint.
Sensor positions
threshold midway
between taught conditions
Darkest
(no signal)
Most Light
(saturated
signal)
Output OFF
Output ON
2nd Taught
Condition
1st Taught
Condition
Position
adjusted by
Manual Adjust
Figure 2. Static TEACH (Light Operate shown)
Bar Graph LED Following TEACH
Relative Signal Difference / Recommendation
6 to 8
Excellent: Very stable operation
4 to 5
Good: Minor sensing variables may affect sensing reliability
2 to 3
Low: Minor sensing variables may affect sensing reliability
1
Unreliable: Consider an alternate sensing scheme
1. Access the TEACH Mode.
Method
Action
Result
Push Button2
Press and hold the Static button > 2
seconds.
•
Power LED: OFF
•
Output LED: ON
•
Status LEDs: LO & DO
alternately flash
•
Bar graph: OFF
Remote Input3 No action is required; the sensor is ready for 1st TEACH condition.
2. TEACH the Output ON condition.
Method
Action
Result
Push Button
a. Present the Output ON condition.
b. Click the Static button.
•
Power LED: OFF
•
Output LED: Flash, then OFF
•
Status LEDs: LO & DO
alternately flash
•
Bar graph: OFF
Remote Input
a. Present the Output ON condition.
b. Single-pulse the remote line.
T
3. TEACH the Output OFF condition.
Method
Action
Result
Push Button
a. Present the Output OFF condition.
b. Click the Static button.
TEACH Accepted
•
Power LED: ON
•
Bar graph: One LED flashes to
show relative contrast (good
signal difference shown; see
table above)
Sensor returns to Run mode.
TEACH Unacceptable
•
Power LED: OFF
•
Bar graph: #1, 3, 5, 7
alternately flash to show failure
Sensor returns to the "TEACH Output ON
condition".
Remote Input
a. Present the Output OFF condition.
b. Single-pulse the remote line.
T
2 0.04 seconds
≤
"Click"
≤
0.8 seconds
3 0.04 seconds
≤
T
≤
0.8 seconds
D10 Expert
™
Series with Bar Graph Display and Discrete Output
P/N 117830 Rev. G
www.bannerengineering.com - Tel: +1-763-544-3164