background image

2

 Visible when Motion = Enabled 

Add New

Startup

Delete

Stored Inspections

Sensors

Properties

Inspection ID

Motion 

3

Motion 

2

Number of Edges

Sensitivity

Rotation

Area

ROI Type

Intensity Range

Area Range

Pass Count

Blemish

ROI Type

Sensitivity

Edge Length Range

Pass Count

Match

ROI Type

Percent Match

Rotation Range

Pass Count

Sort

Saved Patterns

Percent Match

Rotation Range

Pass Criteria

Inspection Name

Set Name / ID

3

 Not available in Match and Sort

Inspection

Timeout

Select

Timeout

Average Color 

1

ROI and Mask

Intensity Range

Color Compare 

1

ROI and Mask

Color Tolerance

Color Area 

1

Color Select

Area Range

Pass Count

Tolerance

Color Space

Intensity Tolerance

ROI and Mask

Color models only

continued

Figure 7. Menu Map - Part 1

 

 

iVu Plus TG and Color Gen2 Image Sensors

4

www.bannerengineering.com - Tel: +1-763-544-3164

P/N 178442 Rev. C

Содержание Color Gen2

Страница 1: ...N Electrostatic Discharge Avoid the damage that electrostatic discharge ESD can cause to the Sensor Always use a proven method for preventing electrostatic discharge when installing a lens or attachin...

Страница 2: ...re Color Description Direction 1 White Output 1 Output 2 Brown 10 V dc to 30 V dc Input 3 Green Output 2 Output 4 Yellow Strobe Out 5 V dc only Output 5 Gray Remote Teach Input 6 Pink External Trigger...

Страница 3: ...sensor inspection The green annotations indicate the object passes and the red annotations indicate a failure This sample inspection failed as shown by the red X next to the Display mode button Regio...

Страница 4: ...Count Sort Saved Patterns Percent Match Rotation Range Pass Criteria Inspection Name Set Name ID 3 Not available in Match and Sort Inspection Timeout Select Timeout Average Color 1 ROI and Mask Inten...

Страница 5: ...cons Icon Description The Main Menu icon is on the bottom left corner of the display on the Home screen Click this icon to access sub menus that are used to set up the iVu The Inspection menu icon is...

Страница 6: ...hrough and select a circular elliptical or rectangular shaped mask The Elliptical Mask icon is on the left side of the display when a mask is selected Click this icon to cycle through and select a cir...

Страница 7: ...actual objects a Go to Imager White Balance b Move and adjust the white balance Region of Interest ROI to surround a white or gray object in the Field of View FOV If there is none place a piece of wh...

Страница 8: ...e separately Adjust the Focus on a C Mount Lens Model 1 Remove the lens enclosure 2 Adjust the focus while monitoring the focus number To ensure the best image adjust the focus until the focus number...

Страница 9: ...Sensor Use a Sort sensor to recognize and sort up to ten different patterns within the same inspection Teach each reference pattern during setup Store reference patterns in one of ten pattern memory l...

Страница 10: ...milliseconds Note If the interval is less than the inspection time missed triggers will occur Free Run the iVu automatically runs continuous inspections Industrial Ethernet Only only Trigger commands...

Страница 11: ...l Ethernet A bi directional communication channel that allows the user to control the device and access device results using Ethernet IP 1 Modbus TCP PCCC or PROFINET 2 protocol Data Export Used to ex...

Страница 12: ...it is returned to the factory is found to have been defective during the warranty period This warranty does not cover damage or liability for misuse abuse or the improper application or installation...

Отзывы: