Technical data • Complete system
26
Panel PC 2100 swing arm user's manual V1.12
2.2.1.2 Minimum ambient temperature for worst-case operation
All specifications apply to non-condensing operation.
E3815
1.46 GHz
E3825
1.33 GHz
E3826
1.46 GHz
E3827
1.75 GHz
E3845
1.91 GHz
All temperature values in degrees
Celsius (°C) at 500 m above sea level, non-condensing.
5PPC2100.BY01-001
5PPC2100.BY1
1-001
5PPC2100.BY22-001
5PPC2100.BY34-001
5PPC2100.BY44-001
Minimum ambient temperature
-20
-20
-20
-20
-20
What else can also be operated at the min.
ambient temperature, or are there any limits?
Location of sensor(s)
5AP92D.1505-0x
✓
✓
✓
✓
✓
5AP92D.1906-0x
0
0
0
0
0
5AP93D.185B-0x
0
0
0
0
0
5AP99D.185B-0x
0
0
0
0
0
5AP93D.215C-0x
0
0
0
0
0
5AP99D.215C-0x
0
0
0
0
0
5AP99D.215I-0x
0
0
0
0
0
5AP93D.240C-0x
0
0
0
0
0
Display units
5AP99D.240C-0x
0
0
0
0
0
Display - See temperature
sensor position
5CFAST.xxxx-00 ≥ Rev. E0
✓
✓
✓
✓
✓
CFast cards
5CFAST.xxxx-10
✓
✓
✓
✓
✓
-
5ACCIF01.FPCC-000
✓
✓
✓
✓
✓
5ACCIF01.FPCS-000
✓
✓
✓
✓
✓
5ACCIF01.FPLK-000
✓
✓
✓
✓
✓
5ACCIF01.FPLS-000
✓
✓
✓
✓
✓
5ACCIF01.FPLS-001
✓
✓
✓
✓
✓
5ACCIF01.FPSC-000
✓
✓
✓
✓
✓
5ACCIF01.FPSC-001
✓
✓
✓
✓
✓
Interface options
5ACCIF01.ICAN-000
✓
✓
✓
✓
✓
-
Table 11: Minimum ambient temperature for worst-case operation
2.2.1.3 How to determine minimum and maximum ambient temperatures
1. Select the system unit.
2. The "Minimum/Maximum ambient temperature" row shows the minimum/maximum ambient temperature for
the complete system, including the respective system unit.
Information:
Maximum temperature data is for operation at 500 meters. The maximum ambient temperature is
typically derated by 1°C per 1000 meters (starting at 500 meters above sea level).
3. Incorporating additional interface options and CFast cards can change the temperature limits of a PPC2100
system.
4. The mounting orientation of the Panel PC 2100 may result in limitations. For more information, see section
"Mounting orientations" on page 23
If there is a
"✓"
next to the component, it can be used at the minimum/maximum ambient temperature of the
complete system without problems.
If there is a specific temperature next to the component, for example "45", then the ambient temperature of the
complete PPC2100 system is not permitted to exceed this temperature.