Software • RFID command set
Chapter 4 Software
Panel PC 2100 swing arm user's manual V1.12
225
16.5 Error messages and numbers
Operating errors
Operating errors
Value
Name
Description
0
ERR_NONE
No errors (OK)
1
ERR_OTHER
Other operating error, unrecognized command
2
ERR_PARAMETER
Incorrect number of parameters
3
ERR_AUTH
Authentication error (A or B)
4
ERR_SECTOR
Invalid range for sector (0-63)
5
ERR_BLOCK_SRC
Invalid range for source block (0-255)
6
ERR_WRITE
No data found to write
7
ERR_KEY_EE
No key found for writing
8
ERR_KEY_STORE
Key could not be saved
9
ERR_BLOCK_DST
Invalid range for target block (0-255)
10
ERR_NO_TAG
No tag in range
11
ERR_BLOCK_NUM
Incorrect values for source/target blocks
12
ERR_TAG_NUM
Invalid tag number
13
ERR_KEY
Invalid key
14
ERR_REMOTE
X-modem firmware update canceled (not used)
15
ERR_SYNC
X-modem firmware update packet start not found (not used)
16
ERR_RETRY
X-modem firmware update number of retry attempts (not used)
17
ERR_READ
Data could not be read
18
ERR_INCDECRES
Error accessing the VALUE block
19
ERR_LOCK
Could not not lock block
20
ERR_AFI
Error writing the AFI value
21
ERR_DSFID
Error writing the DSFID value
22
ERR_SYSINFO
Could not read system information
23
ERR_INVENTORY
Could not execute inventory command due to incorrect parameter (value) or internal RFID stack
error
24
ERR_STAY_QUIET
Could not set specified ISO tag to STAY_QUIET (no longer accessible)
25
ERR_RESET2READY
Could not set specified ISO tag to READY (after a preceding STAY_QUIET)
Table 225: Operating errors