2.2 Environmental characteristics
2.2.1 Temperature specifications
Since the various system units can be combined with a display unit, there are many different possible configurations
with varying minimum and maximum ambient temperatures. An overview is provided in the following tables.
Information:
The minimum and maximum specified ambient temperatures for operation were determined under
worst-case conditions. Experience has shown that higher ambient temperatures can be reached in
typical applications, e.g. those in Microsoft Windows. Testing and evaluation must be performed on-
site by the user (temperatures can be read in BIOS or with the B&R Control Center).
Information regarding worst-case conditions
•
Thermal Analysis Tool (TAT V4.3.4.13.01) from Intel for simulating a 100% processor load
•
BurnInTest tool (BurnInTest V7.0 Pro from Passmark Software) for simulating a 100% load on the interface
via loopback adapters (USB interfaces)
•
Maximum system expansion and power consumption
2.2.1.1 Maximum ambient temperature during operation
E3815
1.46 GHz
E3825
1.33 GHz
E3826
1.46 GHz
E3827
1.75 GHz
E3845
1.91 GHz
All temperature values in degrees
Celsius (°C) at 500 m above sea level.
The maximum ambient temperature is typ-
ically derated by 1°C per 1000 meters
(starting at 500 meters above sea level).
5PPC2100.BY01-001
5PPC2100.BY1
1-001
5PPC2100.BY22-001
5PPC2100.BY34-001
1)
5PPC2100.BY44-001
1)
Maximum ambient temperature
50
50
50
40
40
What else can also be operated at the max.
ambient temperature, or are there any limits?
Location of sensor(s)
5AP92D.1505-0x
✓
✓
✓
✓
✓
5AP92D.1906-0x
✓
✓
✓
✓
✓
5AP93D.185B-0x
✓
✓
✓
✓
✓
5AP99D.185B-0x
✓
✓
✓
✓
✓
5AP93D.215C-0x
40
40
40
✓
✓
5AP99D.215C-0x
1)
40
40
40
✓
✓
5AP99D.215I-0x
35
35
35
30
30
5AP93D.240C-0x
40
40
40
✓
✓
Display units
5AP99D.240C-0x
40
40
40
✓
✓
Display - See temper- ature sensor position
5CFAST.xxxx-00 ≥ Rev. E0
45
45
45
✓
✓
CFast cards
5CFAST.xxxx-10
45
45
45
✓
✓
-
5ACCIF01.FPLS-000
1)
✓
✓
✓
✓
✓
Interface options
5ACCIF01.FPSC-000
1)
✓
✓
✓
✓
✓
-
1) A total derating of 5°C applies when using the 5PPC2100.BY34-001 or 5PPC2100.BY44-001 with the 5AP99D.215C-0x and
5ACCIF01.FPLS-000 or 5ACCIF.FPSC-000.
Table 10: Maximum ambient temperature during operation