background image

WARNING! Some dust particles created by power sanding, sawing, 

grinding, drill and other construction jobs contain chemicals known 

to cause cancer, birth defects or other reproductive harm. 

Some 

examples of these chemicals are:

•  Lead from lead-based paints. 

•  Crystalline silica from bricks and cement and other masonry products. 

•  Arsenic and chromium from chemically treated timber. 

Your risk from these exposures varies, depending upon how often you do 

this type of work. To reduce your exposure to these dusts:

•  Work in a well-ventilated.

•  Work with approved protective equipment, such as those dust masks 

that are specially designed to filter microscopic particles.

VIBRATION 

The European Physical Agents (Vibration) Directive has been brought in to help reduce 

hand arm vibration syndrome injuries to power tool users. The directive requires power 

tool manufacturers and suppliers to provide indicative vibration test results to enable 

users to make informed decisions as to the period of time a power tool can be used 

safely on a daily basis and the choice of tool. 

SEE TECHNICAL SPECIFICATIONS IN THE INSTRUCTION MANUAL FOR THE 

VIBRATION LEVELS OF YOUR TOOL.

The declared vibration emission value should be used as a minimum level and should 

be used with the current guidance on vibration. 

Calculating the actual period of use can be difficult and the HSE website has further 

information. 

The declared vibration total value has been measured in accordance withEN 60745-1 

and EN 60745-2-6 and may be used for compare one tool with another. 

The declared vibration total value may also be used in a preliminary assessment of 

exposure.

10

Содержание PRH850C

Страница 1: ...PRH850C EAN 3663602794790 ORIGINAL INSTRUCTIONS V30318...

Страница 2: ...Safety instructions 6 Product description 13 Assembly 15 Use 17 Care maintenance 21 Guarantee 25 Declaration of conformity 26 2...

Страница 3: ...1 x1 WARNING Please read all safety warnings carefully and be sure that they are fully understood before handling the tool 3...

Страница 4: ...Product description 1 2 3b 3 3a 4 5 6 7 8 9 A 2 1 3 2 B 1 2 2 4 3 1 4...

Страница 5: ...C D x 2 1 3 9 8 2 1 3 3b 3a E F 7 90 G 5...

Страница 6: ...reduce risk of electric shock b Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is eart...

Страница 7: ...safer at the rate for which it was designed b Do not use the power tool if the switch does not turn it on and off Any power tool that cannot be controlled with the switch is dangerous and must be repa...

Страница 8: ...ill Do not drill above shoulder height or below Knee height as the drill cannot be securely held j Never drill holes that are above the declared maximum size in the manual k This drill is not designed...

Страница 9: ...oken into very fine dust also known as Respirable Crystalline Silica or RCS during many common tasks such as cutting drilling and grinding Breathing in very fine particles of crystalline silica can le...

Страница 10: ...e has been brought in to help reduce hand arm vibration syndrome injuries to power tool users The directive requires power tool manufacturers and suppliers to provide indicative vibration test results...

Страница 11: ...sures to protect the operator that are based on an estimation of exposure in the actual conditions of use taking account of all parts of the operating cycle such as the times when the tool is switched...

Страница 12: ...fingers going white as well as specific diseases such as carpal tunnel syn drome To reduce this risk when using the product always wear protective gloves and keep your hands warm RESIDUAL RISKS Even...

Страница 13: ...ries and damage to property Always wear eye protection Always wear ear protection Wear a dust mask Wear protective gloves Lock to tighten or secure Unlock to loosen Note Remark Caution Warning Wrong C...

Страница 14: ...ty Concrete 26 mm Wood 35 mm optional chuck adapter required Metal 13 mm optional chuck adapter required Protection class Weight Approx 4 kg Sound pressure level LpA 88 5 dB A Sound power level LWA 99...

Страница 15: ...so includes suitable personal protective equipment WARNING The product must be fully assembled before operation Do not use a product that is only partly assembled or assembled with damaged parts Wear...

Страница 16: ...lightly grease the shank end of the SDS Plus drill bit 2 Pull the chuck sleeve 2 backward and hold it in position 3 Insert the SDS Plus drill bit chisel To insert it completely until stop combine the...

Страница 17: ...e brick and stone when equipped with SDS Plus bits It is also suitable for coarse drilling operations into wood wood similar materials plastic and metal when using an optional keyed drill chuck Before...

Страница 18: ...a complete stop Always ensure that the mode selector is adjusted to the correct position depending on the intended operation Do not use the product with the switch in any intermediate position Turn t...

Страница 19: ...auxiliary handle status regularly during work refit or replace it if necessary 02 Drilling Drilling into wood wood similar materials plastic or metal could be applied by means of a suitable keyed dri...

Страница 20: ...g of the drill bit See Fig F G 2 Always place the drill tip directly on the point to be drilled first and then switch the product on 04 Chiselling Choose a suitable SDS Plus chisel for your applicatio...

Страница 21: ...t with high pressure air max 3 bar 4 Check for worn or damaged parts Replace worn parts as necessary or contact an authorised service centre for repair before using the product again Do not use chemic...

Страница 22: ...which is coloured blue must be connected to the terminal which is marked with N or coloured black The wire which is coloured brown must be connected to the terminal which is marked L or coloured red 1...

Страница 23: ...t it from slipping or falling over Storage 1 Switch the product off and disconnect it from the power supply 2 Clean the product as described above 3 Store the product and its accessories in a dark dry...

Страница 24: ...ct to power supply 1 2 Check by a specialist electrician 2 Product does not reach full power 2 1 Extension cord not suitable for operation with this product 2 2 Power source e g generator has too low...

Страница 25: ...an authorised agent Cosmetic damage Damage caused by foreign objects substances or accidents Accidental damage or modification Failure to follow manufacturer s guidelines Loss of use of the goods This...

Страница 26: ...e following harmonized standard were made EN60745 1 2009 A11 2010 EN60745 2 6 2010 2014 30 EU Electromagnetic Compatibility directive References to the following harmonized standard were made EN 55014...

Страница 27: ...eldon Square London W2 6PX United Kingdom www kingfisher com products Distributor B Q plc Chandlers Ford Hants SO53 3LE United Kingdom www diy com Screwfix Direct Limited Trade House Mead Avenue Yeovi...