Bandit
53
Copyright 12/17
MODELS 2890SP/2900T
Thismachineisequippedwith“Petro-CanadaHydrexXV”hydraulicfluid.Itisrecommendedtoreplacewith
thesame.“Petro-CanadaHydrexXV”isanallseasonhydraulicfluid.Thisisapremiumperformance,long
lifeanti-wear,hydraulicfluid,designedforallseasonuseinheavydutyhydraulicsystems.“Petro-Canada
Hydrex XV” allows year round use under wide extremes of temperature. It allows the hydraulic system to
start at temperatures as low as -40°C/-40°F, under no load conditions and it improves lubrication of hydraulic
components at high operating temperatures. It will also help protect against hydraulic failures during the
wide temperature swings of spring and fall.To find the closest “Petro-Canada Hydrex XV” dealer call
1-888-284-4572.
Multi Viscosity motor oils are not recommended to mix with “Petro-Canada Hydrex XV” hydraulic oil. AW oils
maymixwith“Petro-CanadaHydrexXV”hydraulicoil.Thefollowingarespecificationsandauthorizationsof
compatible oils. Only a high quality anti-wear (AW) hydraulic oil containing foam, corrosion, rust and oxidation
inhibitors should be used. This viscosity grade depends on the oil temperature in service, based on the climate
and operating conditions.
HYDRAULICS
It is very important after you have operated a new machine for approximately an hour to shut down the machine
andrecheckallhydraulicfittings.Relieveallpressureandretightenasneeded.
DO NOT GO NEAR HYDRAULIC LEAKS! High pressure oil easily punctures skin causing serious injury, gangrene,
ordeath.Avoidburnsfromfluid.Hotfluidunderpressurecancausesevereburns.DONOTusefingersorskinto
checkforleaks.Lowerloadorrelievehydraulicpressurebeforelooseningfittings.Relieveallpressureinthesystem
beforedisconnectingthelines,hoses,orperformingotherwork.Useapieceofcardboardtofindleaks.Neveruse
your bare hands. Allow system to cool down to ambient temperature before opening any coolant or hydraulic oil
system.
In cold weather situations let your hydraulic system idle for approximately 15 minutes to allow the system to warm
up to operating temperature.
WARNING
!
DO NOT operate this machine unless all hydraulic control devices operate properly. They must function,
shift and position smoothly and accurately at all times. Faulty controls can cause personal injury!
WARNING
!
HYDRAULIC FLUID REQUIREMENTS
Hydrex XV
ISO 22, AW
ISO 32, AW
ISO 46, AW ISO 68, AW ISO 100, AW
Viscosity Index
>235
>95
>95
>95
>95
>95
Flash Point
>240°C/464°F >200°C/395°F >210°C/410°F >220°C/430°F >220°C/430°F >240°C/464°F
Oxidations
Stability
(ASTM D0943)
>9,000 Hours >3,000 Hours >3,000 Hours >3,000 Hours >3,000 Hours >3,000 Hours
Cold Start-up,
No Load, Max -40°C/-40°F -34°C/-29°F -26°C/-14°F
19°C/-3°F
-9°C/16°F
-4°C/24°F
HYDRAULICS
Содержание 2890SP
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 25: ...Bandit 19 Copyright 12 17 MODELS 2890SP 2900T CONTROLS MACHINE ORIENTATION REFERENCE RIGHT LEFT BACK FRONT...
Страница 38: ...Bandit 32 Copyright 12 17 MODELS 2890SP 2900T MAINTENANCE RIGHT LEFT BACK FRONT MACHINE ORIENTATION REFERENCE...
Страница 98: ...Bandit 92 Copyright 12 17 MODELS 2890SP 2900T SERVICE RECORD SERVICERECORD DATE DESCRIPTION AMOUNT...
Страница 116: ......
Страница 118: ......
Страница 120: ...SERVICE RECORD DATE DESCRIPTION AMOUNT...