p. 4 - Specifications
SPECIFICATIONS
Descriptions:
- Dimensions:
- Weight:
- Max. Mains supply failure:
- Reaction time:
- Fog ejection image:
Fog generator:
- Fog ejection capacity:
- Fog ejection pressure:
- Maximum fog ejection period:
- Warm-up time:
- Max./min. Environmental temp.:
- Maximum heat loss:
- Heat exchange capacity:
- Nominal ejected droplet size:
HY-3
pack:
- HY-3 fluid contents:
- Nominal working pressure:
- Maximum allowed
internal pressure:
- Construction material:
- Built-in electronics:
Electrical:
- Min./max mains power supply:
- Nominal 12 V low voltage:
- Max peak current at 230 VAC:
- Average power consumption:
- Capacity heating element:
- Inputs:
- Outputs:
- Current back-up:
- Power control:
- Electronics:
270 mm wide x 365 mm high x 255 mm deep.
28 kg.
Fog gen2 hours and elect24 hours.
1 second between alarm signal and fog ejection.
(standard)
or
Str
(/R0 version)
60°
,
aight ahead
28 m³ filling of space / second with 25 cm eye object.
16 BAR (1.6 Mpa).
18 seconds.
50 minutes from cold condition.
maximum 50°C and minimum 0°C.
40 W/hour.
18 kW/hour.
section 0,0004 mm (full aerosol).
1.4 litre.
16 BAR (1.6 Mpa).
60 BAR (6 Mpa).
rvs 304L and aluminium AlMgS1.
digital temperature sensor and analogue/digital
E²prom memory level.
Tamper switch and control LED.
integrated propellant-expulsion security
direct working 12 V
NC
valve.
208 to 240 VAC at 50 to 60 Hz.
13.1 V DC from 0 tot max. 1 A of load.
3.5 A.
40 W/hour.
750 W.
all inputs are insulated by an opto-coupler.
technical- and tamper outputs are potential free
contacts, guard- and alarm outputs are npn-outputs.
12 V / 2 Ah (sealed lead acid battery).
Pulse width modulator (PWM) through zero cross triac.
Flasch micro-controller, Platina Pt1000 sensor converter,
On board communication with HY-3 pack
On board communication: 6-way connector for
connection to "Control Box" and 5-way plug for
wireless remote control.
BANDIT
240 DB
v.206