P. 28 - Maintenance
MAINTENANCE
Because
BANDIT
is listed as a security device, it is obligatory to regularly perform a function
check.
Every year:
4
Fog expulsion check and failure report check through[OKout].
4
Using the “Control Box” you can easily perform these tests . The LED bar indicates the
quantity of HY-3 fluid present in the HY-3 pack.
4
If the "Control Box" isn’t connected, both tests have to be performed through the controlling
alarm system.
If a fog ejection test is performed, you’ll have to warn all persons in the immediate
surroundings and the responsible person for fire hazard. Make sure no one is looking at
the direction of the ejection mouth. Also read next page First Aid.
4
Vacuum the textile of the
BANDIT
front. The textile also has a function as an air filter for
internal air circulation. After a while dust can be an obstacle for a good internal air
ventilation. In those rooms which contain a higher dust percentage, a more frequent textile
cleaning is advised.
Every 2-years:
4
Replace the internal battery in the unit (2Ah / 12V sealed lead/acid).
F
BANDIT
240 DB
v.206