P. 22 - Communication status  - LEDs - Front LEDs 

    

 Guard

N

  

Alarm 

 

Internal failure

 
       This red LED is on as long as 

BANDIT 

is in guard mode.

             

 
       This red LED is on from the moment 

BANDIT 

switches to alarm mode until the unit is

       put out of guard mode through the guard input [Grdin] or an optional remote control.
       This LED blinks as long as the unit is switched into panic mode
  
       

- This red LED blinks (~ 1 Hz) as long as 

BANDIT 

detects one or more internal failures. The 

unit practically checks continuously on possible internal failures. 
Check list of possible internal failures:

4

the glass fuse F2 (500 mA) which secures [Supply] 12 V power supply is interrupted

4

the heat exchanger can not reach the required temperature due to a broken element

       and/or the over temperature fuse has blown.

4

the glass fuse F3 (6.3 AT) which functions as battery fuse is interrupted.

4

the charge of the connected battery  is too low (bad battery or no battery present).

4

the revs of the internal fan aren’t right

4

the environmental temperature of the HY-3 pack is above 50°C.

4

the MCU measures unreal values or value jumps on one or more of its sensors, which

        indicates broken sensor(s).

- This  red LED blinks fast (~ 2 Hz) as long as 

BANDIT 

detects one or more adjustments, 

which are no real technical failures, but have influence on the normal operational 
behaviour of the fog generator:

4

”‘Red jump” isn’t plugged in.

4

A "Control Box" switch is still 

ON

.

4

The presence of a wrong type of HY-3 pack.

 

HY-3 pack 

(

HY-3 pack 

liquid reserve

)

 
       With a charged 

HY-3 pack,

 

BANDIT 

has 1.4 litre of 

HY-3

 liquid.

       During a fog expulsion, approximately 28 ml of fluid is consumed each second.
       So basically, there is a total of ~ 50 seconds of fog expulsion available. 
       This LED starts blinking as soon as there is less than 15 seconds of fog ejection time 
       available.       
       If this red HY-3 LED blinks, the 

HY-3 pack

 has to be replaced. See page 26.

       The actual fog fluid level can always be read off from the Control Box. See page 19.    

       As long as 

BANDIT 

is in guard mode, this LED will be off. This way the unit never will reveal

       a possible shortage of fog fluid, through its front panel, to the outside world. 

  
       

BANDIT

 240 DB 

v.206

Содержание 240 DB

Страница 1: ...installed in those rooms that contain the most valuable objects by doing so burglary damage is effectively limited to a strict minimum Advantages Fills 28 m of space per second of fog expulsion Extrem...

Страница 2: ...holographic cameleon or broken white Standards Complies with European CE and EMC Standards Complies with International Standard IEC 839 1 3 Approved by the Belgian Ministry of Internal Affairs Complie...

Страница 3: ...n supply fuse to off In case of doubt immediately contact your BANDIT dealer or manufacturer mentioned on the back cover of this manual There are no repairable components inside the appliance Leave al...

Страница 4: ...or Str R0 version 60 aight ahead 28 m filling of space second with 25 cm eye object 16 BAR 1 6 Mpa 18 seconds 50 minutes from cold condition maximum 50 C and minimum 0 C 40 W hour 18 kW hour section 0...

Страница 5: ...t in the direction of fragile objects The powerful fog expulsion could blow down these objects There has to be a free passage area for the ejected fog of at least 5 to 6 metres before it bounces again...

Страница 6: ...or stuck to it with included double sided adhesive tape The device is installed at 6 cm off the floor to avoid possible damage due to cleaning tools or water Hidden mounting of the appliance For inst...

Страница 7: ...shop of 180 m Fog image after 8 sec of fog expulsion The BANDIT 240 has a room filling capacity of 28 m per second This corresponds with 10 m sec The max surface area which can be secured with one de...

Страница 8: ...is tamper secured so be sure that the unit is not in guard mode and that the control room optional is warned Connection to the mains power supply on the left beneath the PCB you ll find a 3 way termin...

Страница 9: ...eds 12 V over input Red White Green Blue Orange Black 5 way connector remote control Red jump PaninV GrdinV F2 F3 F4 6 x Control box PCB connectors Technical output Guard output Alarm output Tamperloo...

Страница 10: ...ns beneath connectors on PCB secured for possible polarity reverse and equipped with RC and LC filter an input has to be stable for at least 0 2 seconds before the new situation is accepted the connec...

Страница 11: ...hout power supply Depending on the position of dipswitch A1 the guard mode will be active with 12 V supply over the input or active without power supply over this input As long as there is a 12 V supp...

Страница 12: ...arm pulse over Alin1 after these 3 minutes will start a new fog expulsion period See also page 21 under temperature protection Configuration of the alarm input Alin Depending on the A2 dip switch posi...

Страница 13: ...ther through 12 V supply or without power supply Depending on the position of dip switch A3 the panic mode will be active with 12 V supply or when there is no power supply over this input As long as t...

Страница 14: ...current the voltage is 13 volt This voltage is practically ripple free 10mV ripple and is used as supply for small external power users such as external inner siren Jumbo LEDand PIR sensors It is als...

Страница 15: ...per of rear cover If the tamper circuit is ok the red Tmp LED will go off as long as you keep the tamper spring pushed in b A HY 3 pack is in the unit and the side hatch is closed c there isn t connec...

Страница 16: ...n HY 3 pack is above 50 C 4The temperature of the heat exchanger is too low to admit a fog expulsion This can mean a the internal over temperature fuse is interrupted b the heat resistance of the heat...

Страница 17: ...unit is in guard mode The transistor output floats as long as the unit isn t in guard mode A common application for this handy Grdout output is to connect this output through a separating relay with...

Страница 18: ...t The transistor conducts as soon as the unit switches to alarm mode or to panic mode The transistor output floats if a the panic mode is switched off or b automatically 3 minutes after the last fog e...

Страница 19: ...d insulated and finished with a general insulation over the complete wire In the packing of the Control Box you ll find the mounting screws and nuts also a 6 way plug in connector with screw connectio...

Страница 20: ...stays closed so no sabotage notice or fog expulsion while opening the side hatch The green LED on the switch is on The front LED internal failure blinks fast 2Hz This allows a fog ejection test each...

Страница 21: ...ady F F One of tasks of the integrated Power Saver is to take care that the temperature of the heat exchanger will not raise higher than necessary to produce the adjusted fog quantity The temperature...

Страница 22: ...4the environmental temperature of the HY 3 pack is above 50 C 4the MCU measures unreal values or value jumps on one or more of its sensors which indicates broken sensor s This red LED blinks fast 2 Hz...

Страница 23: ...red error info LED Error on the PCB If this LED starts blinking a failure is reported whereby the frequency of blinking reveals the kind of failure The blinking sequence is built up in repeating time...

Страница 24: ...ead out and executed The position of dip switches B1 and B2 determine the function of both channels ch1 and ch2 There are a total of 4 adjustment combinations Both transmitter buttons function if guar...

Страница 25: ...nd or cold surfaces As soon there is an air flow ventilation this practically invisible and water soluble thin film will evaporate within 24 hours The lower the adjusted fog expulsion period the lower...

Страница 26: ...ent HY 3 pack and calculates by means of the passed through parameters how much fluid still is available in theHY 3 pack If the level seems to have gone below the adjusted minimum value see page 22 HY...

Страница 27: ...3 pack in the upper layer of the HY 3 pack box Unscrew the HY 3 pack grip and screw it on the new HY 3 pack Pull off the red transport protection cap and put it on the old HY 3 pack Push evenly the H...

Страница 28: ...tem If a fog ejection test is performed you ll have to warn all persons in the immediate surroundings and the responsible person for fire hazard Make sure no one is looking at the direction of the eje...

Страница 29: ...ia panic instantly persons who are over sensitive to stressing situations e g hyperventilate racing pulse etc persons who are strong asthmatic or exceptionally sensitive to irritation of the respirato...

Страница 30: ...12V over Grdin So if relevant output of alarm system active npn transistor in conduction the GrdinV LED is lit and BANDIT is in guard mode A2 position OFF if there is a transition from 12V to 0 V ove...

Страница 31: ...ng adjusted period dip block C Alarmcontact Tampercontact 12 V in _ PIR radar sensor Why to use a confirmation sensor To postpone the transition to alarm mode until a local zone detector confirms the...

Страница 32: ...al is active relay contact closed GrdinV LED is lit and BANDIT is in guard mode A2 Position OFF if there is a transition of 12V to 0 V over Alin contact opens while BANDIT is in guard the alarm mode i...

Страница 33: ...ods that are stolen even though BANDIT is functioning as supposed or if it is malfunctioning due to an internal or external failure We advise the installer to inform his insurance company that they wi...

Страница 34: ...tion with BANDIT main PCB The purpose of these electronics is to measure how much fluid is present in the pressure vessel and to store all production and filling data of the HY 3 pack If the pressure...

Отзывы:

Похожие инструкции для 240 DB