P. 22 - Communication status - LEDs - Front LEDs
Guard
N
N
Alarm
N
Internal failure
This red LED is on as long as
BANDIT
is in guard mode.
This red LED is on from the moment
BANDIT
switches to alarm mode until the unit is
put out of guard mode through the guard input [Grdin] or an optional remote control.
This LED blinks as long as the unit is switched into panic mode
- This red LED blinks (~ 1 Hz) as long as
BANDIT
detects one or more internal failures. The
unit practically checks continuously on possible internal failures.
Check list of possible internal failures:
4
the glass fuse F2 (500 mA) which secures [Supply] 12 V power supply is interrupted
4
the heat exchanger can not reach the required temperature due to a broken element
and/or the over temperature fuse has blown.
4
the glass fuse F3 (6.3 AT) which functions as battery fuse is interrupted.
4
the charge of the connected battery is too low (bad battery or no battery present).
4
the revs of the internal fan aren’t right
4
the environmental temperature of the HY-3 pack is above 50°C.
4
the MCU measures unreal values or value jumps on one or more of its sensors, which
indicates broken sensor(s).
- This red LED blinks fast (~ 2 Hz) as long as
BANDIT
detects one or more adjustments,
which are no real technical failures, but have influence on the normal operational
behaviour of the fog generator:
4
”‘Red jump” isn’t plugged in.
4
A "Control Box" switch is still
ON
.
4
The presence of a wrong type of HY-3 pack.
N
HY-3 pack
(
HY-3 pack
liquid reserve
)
With a charged
HY-3 pack,
BANDIT
has 1.4 litre of
HY-3
liquid.
During a fog expulsion, approximately 28 ml of fluid is consumed each second.
So basically, there is a total of ~ 50 seconds of fog expulsion available.
This LED starts blinking as soon as there is less than 15 seconds of fog ejection time
available.
If this red HY-3 LED blinks, the
HY-3 pack
has to be replaced. See page 26.
The actual fog fluid level can always be read off from the Control Box. See page 19.
As long as
BANDIT
is in guard mode, this LED will be off. This way the unit never will reveal
a possible shortage of fog fluid, through its front panel, to the outside world.
BANDIT
240 DB
v.206