P. 20 - Control Box operation
Operation and function:
- Bistable switch:
- Bistable switch:
- Monostable switch (pulse switch)
- Monostable switch (pulse switch)
- HY-3 pack level LEDbar (dot mode)
With this switch the fog generator is
disconnected (so no fog ejection) Same
function as “Red Jump” on PCB.
With active switch:
- The internal electronics continue to
function as normal, but
BANDIT
will
always refuse to perform a fog ejection.
- The front LED "internal failure" blinks
fast (~2Hz).
- The red LED on the switch is on.
This switch permits you to put the
controlling alarm system into an alarm
simulation, whereby the
BANDIT
is also
triggered, but without filling the room with
fog.
If the side hatch (in order to replace the
HY-3 pack) is being opened, the unit will
interrupt the internal sabotage loop. If
this opening is done while the unit is in
guard, the unit is going to perform a fog
ejection. With this switch, you can
prevent this sabotage reaction
With active switch:
- The tamper output stays closed, so no
sabotage notice or fog expulsion while
opening the side hatch.
- The green LED on the switch is on.
- The front LED "internal failure" blinks
fast (~2Hz).
This allows a fog ejection test, each
time this switch is pushed in,
BANDIT
will perform a fog ejection for one
second.
If the volume of the ejected fog during
this one second is enough and normal,
you can be sure that it also will be OK
for longer adjusted fog ejection periods.
Before performing a fog ejection test,
see safety precautions on page 3.
This "LED bar" gives the actual usable
percentage of volume of HY-3 liquid in
the HY-3 pack.
As soon as the orange LED is lit, you’ll
have to replace the HY-3 pack. The unit
also will have its red HY-3 LED on the
front panel blinking.
If there is less than 30% of HY-3 liquid
in reserve (30% = ~15 sec. of fog
ejection time available), you’ll have to
replace the HY-3 pack with a filled one.
As long as this switch is
pushed in, the technical output
[OKout] will be in rest (
COM
and
NO
open), so an internal failure
Will be simulated. This way an
internal failure signal by
BANDIT
can be checked if it is
treated and transmitted
correctly.
90
60
30
0%
HY-3 pack level / niveau / livello
90
60
30
0%
BANDIT
240 DB
v.206
test
test
tech out
tech out
OK
OK