test

P. 20 - Control Box operation

Operation and function:

- Bistable switch:

- Bistable switch:

- Monostable switch (pulse switch)

- Monostable switch (pulse switch)

- HY-3 pack level LEDbar (dot mode)

With this switch the fog generator is 
disconnected (so no fog ejection) Same 
function as “Red Jump” on PCB. 
With active switch:
- The internal electronics continue to 

function as normal, but 

BANDIT

 will 

always refuse to perform a fog ejection.

- The front LED "internal failure" blinks 

fast (~2Hz).

- The red LED on the switch is on. 

This switch permits you to put  the 
controlling alarm system into an alarm 
simulation, whereby the 

BANDIT

 is also 

triggered, but without filling the room with 
fog.

If the side hatch (in order to replace the 
HY-3 pack) is being opened, the unit will 
interrupt the internal sabotage loop. If 
this opening is done while the unit is in 
guard, the unit is going to perform a fog 
ejection. With this switch, you can 
prevent this sabotage reaction
With active switch:
- The  tamper output stays closed, so no  

sabotage notice or fog expulsion while 
opening the side hatch.

- The green LED on the switch is on.
- The front LED "internal failure" blinks 

fast (~2Hz).

This allows a fog ejection test, each 
time this switch is pushed in, 

BANDIT 

will perform a fog ejection for one 
second.

If the volume of the ejected fog during 
this one second is enough and normal, 
you can be sure that it also will be OK 
for longer adjusted fog ejection periods.
Before performing a fog ejection test, 
see safety precautions on page 3.

This "LED bar" gives the actual usable 
percentage of volume of  HY-3 liquid in 
the HY-3 pack.
As soon as the orange LED is lit, you’ll 
have to replace the HY-3 pack. The unit 
also will  have its red HY-3 LED on the 
front panel blinking.
If there is less than  30% of HY-3 liquid 
in reserve (30% = ~15 sec. of fog 
ejection time available), you’ll have to 
replace the HY-3 pack with a filled one.

As long as this switch is 
pushed in, the technical output 
[OKout] will be in rest (

COM

 and 

NO

 open), so an internal failure

Will be simulated. This way an 
internal failure signal by 

BANDIT  

can be checked if it is 

treated and transmitted 
correctly.
 

90 

60 

30 

0% 

HY-3 pack level / niveau / livello

90 

60 

30 

0% 

BANDIT

 240 DB 

v.206

test

test

tech out

tech out

OK

OK

Содержание 240 DB

Страница 1: ...installed in those rooms that contain the most valuable objects by doing so burglary damage is effectively limited to a strict minimum Advantages Fills 28 m of space per second of fog expulsion Extrem...

Страница 2: ...holographic cameleon or broken white Standards Complies with European CE and EMC Standards Complies with International Standard IEC 839 1 3 Approved by the Belgian Ministry of Internal Affairs Complie...

Страница 3: ...n supply fuse to off In case of doubt immediately contact your BANDIT dealer or manufacturer mentioned on the back cover of this manual There are no repairable components inside the appliance Leave al...

Страница 4: ...or Str R0 version 60 aight ahead 28 m filling of space second with 25 cm eye object 16 BAR 1 6 Mpa 18 seconds 50 minutes from cold condition maximum 50 C and minimum 0 C 40 W hour 18 kW hour section 0...

Страница 5: ...t in the direction of fragile objects The powerful fog expulsion could blow down these objects There has to be a free passage area for the ejected fog of at least 5 to 6 metres before it bounces again...

Страница 6: ...or stuck to it with included double sided adhesive tape The device is installed at 6 cm off the floor to avoid possible damage due to cleaning tools or water Hidden mounting of the appliance For inst...

Страница 7: ...shop of 180 m Fog image after 8 sec of fog expulsion The BANDIT 240 has a room filling capacity of 28 m per second This corresponds with 10 m sec The max surface area which can be secured with one de...

Страница 8: ...is tamper secured so be sure that the unit is not in guard mode and that the control room optional is warned Connection to the mains power supply on the left beneath the PCB you ll find a 3 way termin...

Страница 9: ...eds 12 V over input Red White Green Blue Orange Black 5 way connector remote control Red jump PaninV GrdinV F2 F3 F4 6 x Control box PCB connectors Technical output Guard output Alarm output Tamperloo...

Страница 10: ...ns beneath connectors on PCB secured for possible polarity reverse and equipped with RC and LC filter an input has to be stable for at least 0 2 seconds before the new situation is accepted the connec...

Страница 11: ...hout power supply Depending on the position of dipswitch A1 the guard mode will be active with 12 V supply over the input or active without power supply over this input As long as there is a 12 V supp...

Страница 12: ...arm pulse over Alin1 after these 3 minutes will start a new fog expulsion period See also page 21 under temperature protection Configuration of the alarm input Alin Depending on the A2 dip switch posi...

Страница 13: ...ther through 12 V supply or without power supply Depending on the position of dip switch A3 the panic mode will be active with 12 V supply or when there is no power supply over this input As long as t...

Страница 14: ...current the voltage is 13 volt This voltage is practically ripple free 10mV ripple and is used as supply for small external power users such as external inner siren Jumbo LEDand PIR sensors It is als...

Страница 15: ...per of rear cover If the tamper circuit is ok the red Tmp LED will go off as long as you keep the tamper spring pushed in b A HY 3 pack is in the unit and the side hatch is closed c there isn t connec...

Страница 16: ...n HY 3 pack is above 50 C 4The temperature of the heat exchanger is too low to admit a fog expulsion This can mean a the internal over temperature fuse is interrupted b the heat resistance of the heat...

Страница 17: ...unit is in guard mode The transistor output floats as long as the unit isn t in guard mode A common application for this handy Grdout output is to connect this output through a separating relay with...

Страница 18: ...t The transistor conducts as soon as the unit switches to alarm mode or to panic mode The transistor output floats if a the panic mode is switched off or b automatically 3 minutes after the last fog e...

Страница 19: ...d insulated and finished with a general insulation over the complete wire In the packing of the Control Box you ll find the mounting screws and nuts also a 6 way plug in connector with screw connectio...

Страница 20: ...stays closed so no sabotage notice or fog expulsion while opening the side hatch The green LED on the switch is on The front LED internal failure blinks fast 2Hz This allows a fog ejection test each...

Страница 21: ...ady F F One of tasks of the integrated Power Saver is to take care that the temperature of the heat exchanger will not raise higher than necessary to produce the adjusted fog quantity The temperature...

Страница 22: ...4the environmental temperature of the HY 3 pack is above 50 C 4the MCU measures unreal values or value jumps on one or more of its sensors which indicates broken sensor s This red LED blinks fast 2 Hz...

Страница 23: ...red error info LED Error on the PCB If this LED starts blinking a failure is reported whereby the frequency of blinking reveals the kind of failure The blinking sequence is built up in repeating time...

Страница 24: ...ead out and executed The position of dip switches B1 and B2 determine the function of both channels ch1 and ch2 There are a total of 4 adjustment combinations Both transmitter buttons function if guar...

Страница 25: ...nd or cold surfaces As soon there is an air flow ventilation this practically invisible and water soluble thin film will evaporate within 24 hours The lower the adjusted fog expulsion period the lower...

Страница 26: ...ent HY 3 pack and calculates by means of the passed through parameters how much fluid still is available in theHY 3 pack If the level seems to have gone below the adjusted minimum value see page 22 HY...

Страница 27: ...3 pack in the upper layer of the HY 3 pack box Unscrew the HY 3 pack grip and screw it on the new HY 3 pack Pull off the red transport protection cap and put it on the old HY 3 pack Push evenly the H...

Страница 28: ...tem If a fog ejection test is performed you ll have to warn all persons in the immediate surroundings and the responsible person for fire hazard Make sure no one is looking at the direction of the eje...

Страница 29: ...ia panic instantly persons who are over sensitive to stressing situations e g hyperventilate racing pulse etc persons who are strong asthmatic or exceptionally sensitive to irritation of the respirato...

Страница 30: ...12V over Grdin So if relevant output of alarm system active npn transistor in conduction the GrdinV LED is lit and BANDIT is in guard mode A2 position OFF if there is a transition from 12V to 0 V ove...

Страница 31: ...ng adjusted period dip block C Alarmcontact Tampercontact 12 V in _ PIR radar sensor Why to use a confirmation sensor To postpone the transition to alarm mode until a local zone detector confirms the...

Страница 32: ...al is active relay contact closed GrdinV LED is lit and BANDIT is in guard mode A2 Position OFF if there is a transition of 12V to 0 V over Alin contact opens while BANDIT is in guard the alarm mode i...

Страница 33: ...ods that are stolen even though BANDIT is functioning as supposed or if it is malfunctioning due to an internal or external failure We advise the installer to inform his insurance company that they wi...

Страница 34: ...tion with BANDIT main PCB The purpose of these electronics is to measure how much fluid is present in the pressure vessel and to store all production and filling data of the HY 3 pack If the pressure...

Отзывы:

Похожие инструкции для 240 DB