BA230
28
UK
BA230
29
UK
To access this procedure, select the menu C21.
CAUTION
: Always start with the gate fully closed.
The times are programmed by means of successive start pulses. During the time self-learning phase, C21 blinks
continuously on the display.
During the time self-learning phase, motion always occurs at a non-decelerated speed.
If you want deceleration, remember to activate the option (menu C11) before starting the self-learning procedure:
in this case, the microprocessor will automatically calculate the deceleration time (approximately 20% of the total
time), which will be added at the end of the run time.
The thus defined times can subsequently be modified manually by accessing the dedicated menus and changing
the numerical data.
TIME LEARNING PROCEDURE
1-motor configuration
the gate starts opening.
• START
• When the gate arrives at the desired opening position
START
the gate stops.
• Counting of the pause time during opening starts.
• When the desired pause time has elapsed
START
the gate starts closing.
• When the gate arrives at the closing position
START
the gate stops.
2-motor configuration
the gate 1 starts opening.
• START
• When the gate 1 arrives at the desired opening position
START
the gate 1 stops.
• Counting of the pause time during opening starts.
• When the desired pause time has elapsed
START
the gate 2 starts closing.
• Gate 1 automatically starts after 5 seconds.
• Gate 2 automatically starts after 3 seconds.
• When the gate 2 arrives at the desired opening position
START
the gate 2 stops.
• When the gate 2 arrives at the closing position
START
the gate 2 stops.
• When the gate 1 arrives at the closing position
START
the gate 1 stops.
USING THE LIMIT SWITCHES
NB:
In case of deceleration, the deceleration time must be subtracted from the run time
Example: Run time shown on the display
H1=15 H2=20 H3=3
becomes
H1= 12 H2=17 H3=3
• To exit the procedure once the above described steps have been carried out, press the ESC button until the horizontal lines
appear on the display.until the horizontal lines appear on the display.
If the deceleration function is enabled, the limit switches mark the start of the deceleration period. The gate continues the
decelerated motion for the time set in the menus H3 and H6.
Make sure that you set the run times longer than the time necessary to reach the limit switch.
If deceleration is not enabled, the limit switches stop the motion.
DEFAULT SETTINGS
• Parameters type A active:
A1
E
SWING GATE TYPE
A5
E
2 MOTORS
A8
E
AUTOMATIC LOGIC
C4
• Parameters type C active:
C1
E
AUTOMATIC CLOSING ENABLED
E
FAST CLOSING DISABLED
C5
E
PRE-FLASHING ENABLED
C8
E
SAFETY DEVICE TEST DISABLED
C10
E
LIMIT SWITCHES DISABLED
C12
E
DECELERATION DISABLED
C14
E
WATER HAMMER DISABLED
C16
E
FINAL CLOSING STROKE DISABLED
C18
E
HYDRAULIC LOCK RETENTION DISABLED
C20
E
ANTI-CRUSHING DISABLED (NOT IMPLEMENTED)
C21
AUTOMATIC PROGRAMMING DISABLED
C23
E
ELECTROMECHANICAL OPERATOR
F2
• Parameters type F:
F1
10
MOTOR 1 FORCE
10
MOTOR 1 DECELERATION
F3
10
MOTOR 2 FORCE
F4
10
MOTOR 2 DECELERATION
H2
• Parameters type H:
H1
25
MOTOR 1 OPENING TIME
25
MOTOR 1 CLOSING TIME
H3
0
MOTOR 1 DECELERATION TIME
H4
25
MOTOR 2 OPENING TIME
H5
25
MOTOR 2 CLOSING TIME
H7
H6
0
MOTOR 2 DECELERATION TIME
5
GATE 2 PHASE SHIFT TIME DURING OPENING
H8
5
GATE 1 PHASE SHIFT TIME DURING CLOSING
H9
5
PAUSE TIME
H10
5
PEDESTRIAN OPENING TIME
H12
H11
5
PEDESTRIAN PAUSE TIME
0
NUMBER OF CYCLES
H13
0000
INSTALLER CODE
H14
SOFTWARE VERSION