BA230
20
UK
BA230
21
UK
Motor protection and primary transformer.
6 A
FAST
Low-voltage protection and accessories.
315 mA
FAST
F1
F2
JP4
PHOTOCELL 2 input (N.C.).
If not used, jumper with terminal 31
Operation
:
Input active during both opening and closing.
If intercepted, it immediately stops the motion and holds it stopped until the photocell
is freed. Upon release, motion always restarts in opening.
If intercepted when the gate is closed, following a Start command, it does not allow
opening the gate and it will be signalled with 5 fast flashes. Upon release, the gate
will start opening without having to give further commands.
If intercepted during pause, it reloads the pause time.
26
PH2
Not used
27
SAFETY DEVICE input (N.C.).
If not used, jumper with terminal 31
Operation
:
Input active both during opening and closing.
Stops the motion and inverts it for 2 seconds. The gate will remain locked until the
next Start pulse, which will restart it in the obstacle freeing direction.
28
FRAME
PHOTOCELL 1 input (N.C.).
If not used, jumper with terminal 31
Operation
:
Input active only during closing.
Stops the motion and inverts it, fully opening the gate.
When the gate is closed, it is uninfluential.
If intercepted during pause, it reloads the pause time.
30
PH1
COMMON INPUTS/OUTPUTS.
31
COM
ANTENNA GROUND input.
32
GND
ANTENNA SIGNAL input.
33
ANT
JP6
Connector for plug-in radio receiver.
JP7
Closing limit switch input - motor 2 (N.C.).
If not used, disable during programming by enabling the C10 menu.
25
FCCM2
Description
Position
Value
Type
PROTECTION FUSES
PROGRAMMING PROCEDURE AND SYSTEM CONFIGURATION
Not used
29
The system adjustments can be accessed via the display. There are 4 different menus marked with the letters A,
C, F and H.
1
2
33
4
5
To access programming, simultaneously press the OK and ESC
buttons for 3 seconds.
_ _ _ _
_ _ _ _
_ _ _ _
ESC
OK
The letters P A S S appear on the display.
Press the OK button to go to step 3.
Press the ESC button to exit and return to step 1.
ESC
OK
PASS
4 digits ( 0 0 0 0 ) appear on the display of which the first blinks.
Use the + or - buttons to select the first digit of the installer code.
Once you have arrived at the desired digit, confirm with the OK
button and go to step 4.
OK
0
000
-
+
OK
4
0
00
-
+
OK
46
0
0
-
+
The second digit blinks.
Use the + or - buttons to select the second digit of the installer
code.
Once you have arrived at the desired digit, confirm with the OK
button and go to step 5.
The third digit blinks.
Use the + or - buttons to select the third digit of the installer code.
Once you have arrived at the desired digit, confirm with the OK
button and go to step 6.