INSTALLATION
WARNINGS FOR THE USER
INSTALLATION WARNINGS
Use glands adequate to ensure proper mechanical connection of cable and maintain the box protection degree IP55.
(FIG. 2)
In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service.
Periodically check functioning of the safety devices. Any repairs must be carried out by specialised personnel
using original and certified materials.
The appliance is not to be used by children or people with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction.
Do not touch the card for adjustments and/or maintenance.
• Before proceeding with installation, fit a magnetothermal or differential switch with a maximum capacity of 10A
upstream of the system. The switch must guarantee omnipolar separation of the contacts with an opening
distance of at least 3 mm.
• To prevent possible interference, differentiate and always keep the power cables (minimum cross-section
1.5 mm²) separate from the signal cables (minimum cross-section 0.5 mm²).
• Make the connections referring to the following tables and to the attached screen-print. Be extremely careful to
connect in series all the devices that are connected to the same N.C. (normally closed) input, and in parallel all
the devices that share the same N.O. (normally open) input. Incorrect installation or improper use of the
product may compromise system safety.
• Keep all the materials contained in the packaging away from children, since they pose a potential risk.
• The manufacturer declines all responsibility for improper functioning of the automated device if the original
components and accessories suitable for the specific application are not used.
• After installation, always carefully check proper functioning of the system and the devices used.
• This instruction manual addresses persons qualified for installation of "live equipment". Therefore, good
technical knowledge and professional practice in compliance with the regulations in force are required.
• Maintenance must be carried out by qualified personnel.
• Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
• This control unit may only be used for the purpose for which it was designed.
• Check the aim of the final use and make sure that all safety measures are taken.
• Use of the product for purposes different from the intended use has not been tested by the manufacturer,
therefore any work is carried out on full responsibility of the installer.
• Mark the automated device with visible warning plates.
• Warn the user that children or animals may not play or stand around near the door.
• Appropriately protect the danger points (for example, using a sensitive frame).
WARNING: IMPORTANT SAFETY INSTRUCTIONS.
It is very important to follow the present instructions for your own safety.
Please keep this manual.
Description
JP1
Terminal
230 VAC power supply.
1
Position
Signal
PHASE
230 VAC power supply.
2
NEUTR
Ground wire connection.
3
GND
JP2
Flashlight output 230 VAC 40W.
4
LAMP
Flashlight output 230 VAC 40W.
5
LAMP
Operation:
slow flashing during opening, off during
pause, fast flashing during closing.
Motor 1 connection (closing).
6
CLOSE
Motor 1 common.
7
COM
Motor 1 connection (opening).
8
OPEN
Motor 2 connection (closing).
9
CLOSE
Motor 2 common.
10
COM
Motor 2 connection (opening).
11
OPEN
JP5
Electric lock negative.
12
COM
Electric lock +12 Vdc positive - motor 1.
13
EL1
Electric lock +12 Vdc positive - motor 2.
14
EL2
External accessory power supply negative.
15
GND
Warning light output - 24 VAC 3W
max.
16
WARNIN
G LIGHT
Operation:
slow flashing during opening, on fixed during
pause, fast flashing during closing.
+24 Vdc external accessory power supply (photocells, radio, etc.)
17
24Vdc
+24 Vdc external safety device power supply.
18
SEC
JP4
START input (N.O.)
19
START
SLIDING GATE CONFIGURATION:
opens for the time set in the H10 menu.
20
PED
STOP input (N.C.)
If not used, jumper with terminal 31.
21
STOP
SWING GATE CONFIGURATION:
fully opens gate 1.
PEDESTRIAN input (N.O.)
Opening limit switch input - motor 1 (N.C.).
If not used, disable during programming by enabling the C10 menu.
22
FCAM1
Closing limit switch input - motor 1 (N.C.).
If not used, disable during programming by enabling the C10 menu.
23
FCCM1
ELECTRICAL CONNECTIONS: FASTONS
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
CF1 CF3
CF2 CF4
CF5 CF6
CF7 CF8
CF9 CF10
5
4
3
2
1
Primary connection of 230 VAC transformer (black cables)
Secondary connection of 14 VAC transformer (red cables)
Secondary connection of 22 VAC transformer (blue cables)
Motor 2 capacitor connection
Motor 1 capacitor connection
24
FCAM2
Opening limit switch input - motor 2 (N.C.).
If not used, disable during programming by enabling the C10 menu.