DIP 6
DIP 10
DIP 8
DIP 9
DIP 7
ON
ON
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
AUTOMATIC CLOSING
LED POWER SUPPLY
FAST CLOSING
DECELERATION
Enables automatic closing after the pause time adjustable with the
trimmer TR2 PAUSE between 2 and 215 seconds.
Supplies the LEDs (which will come on depending on the respective con-
tact). After proper installation, the LED power supply can be deactivated
to save energy.
Enables deceleration during both opening and closing when the respective
limit switch is intercepted.
The deceleration speed is adjusted with the trimmer TR6 SLOW.
This function utilises 2 suitably shaped cams (for positioning see
2
).
Disables automatic closing.
Disables the warning LED power supply.
Reduces the pause time to 3 seconds after intervention of one of the
photocells.
Not used.
Disables the fast closing function.
Not used.
Disables the deceleration function.
Requires 2 suitably shaped cams (for positioning see
2
).
16
BSC24
UK
DEFAULT SETTINGS
USE OF THE LIMIT SWITCHES
• DIP 1 and DIP 2 both OFF: Step-by-step with stop
• DIP 3 OFF:
Pre-flashing disabled
• DIP 4 OFF:
Safety device test disabled
• DIP 5 OFF:
Opening photocell disabled
• DIP 6 ON:
Automatic closing enabled
• DIP 7 OFF:
Deceleration disabled
• DIP 8 OFF:
Fast closing disabled
• DIP 9 OFF:
Uninfluential
• DIP 10 ON:
LEDs powered
When using the deceleration function, the board operates
in two different modes depending on whether it is the
opening or the closing phase.
• During opening, deceleration will start when the limit
switch reaches the beginning of the shaped cam.
The motion will stop when the limit switch meets the end
of the shaped part.
• During closing, deceleration will start when the limit
switch reaches the beginning of the shaped cam.
When the limit switch reaches the end of the shaped
part, a full-power stroke is generated to perfectly close
the door.
Motor
off
Deceleration
start
OPENING CAM
Deceleration
start
Start of
final stroke
at full power
CLOSING CAM
2