14
BSC24
UK
ELECTRICAL CONNECTIONS: FASTONS
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Description
M2
M3
M1
Terminal
Used only with dead man's logic to close the door/barrier.
STOP input (N.C.).
If not used, jumper with terminal 8.
WARNING LIGHT output 24V 3W max. (slow flashing during opening, on fixed
with door/barrier open, fast flashing during closing).
3
7
22
Position
Signal
OPT
STOP
SPIA
START input (N.O.).
COMMON INPUTS-OUTPUTS.
COMMON INPUTS-OUTPUTS.
COMMON INPUTS-OUTPUTS.
OPENING LIMIT SWITCH input.
24Vac output to BATTERY CHARGER BOARD.
CLOSING LIMIT SWITCH input.
0Vac output to BATTERY CHARGER BOARD.
+24 Vdc EXTERNAL ACCESSORIES power supply (photocells, radio, etc...).
Negative connection to the BATTERY CHARGER BOARD.
Positive connection to the BATTERY CHARGER BOARD.
COURTESY LIGHT output 24V 10W max.
FLASHLIGHT output 24V 10W max. (slow flashing during opening, off with
door/barrier open, fast flashing during closing).
It can also be connected to the battery charger board.
+24Vdc EXTERNAL SAFETY DEVICES (rail) power supply present only during
the operating cycle.
Connect the devices on which the safety test is to be run to this input (also see
DIP 4).
24V MOTOR output - open.
24V MOTOR output - close.
4
8
15
23
9
16
10
17
11
18
20
21
19
14
12
13
START
COM
COM
COM
FCA
+24 Vac
FCC
0 Vac
+ ACCES
+ SK
- SK
LIGHT
LAMP
+ SAFETY
MOTOR OPEN
MOTOR CLOSE
PHOTOCELL input (N.C.).
If not used, jumper with terminal 8.
5
PHOTO
Description
Position
TRANSFORMER 0 Vac CONNECTION (BLACK CABLE).
1
Signal
0 Vac
TRANSFORMER 18Vac CONNECTION (ORANGE CABLE).
2
18 Vac
TRANSFORMER 24Vac CONNECTION (RED CABLE).
3
24 Vac
6
SAFETY
SAFETY DEVICE input (N.C.).
If not used, jumper with terminal 8 and set DIP 4 to OFF.
1
2
M5
GND
ANT
ANTENNA BRAID input.
ANTENNA SIGNAL input.