15
BSC24
UK
PROTECTION FUSES
FUNCTION PROGRAMMING (DIP SWITCH-SW1)
Description
DIP
Status
Function
Description
Position
Protects the accessories and safety devices power supply.
F1
Value
Type
315 mA
FAST-BLOW
Protects the control unit at the 24Vac power supply input.
F2
6,3 A
FAST-BLOW
Protects the flashlight and courtesy light output.
F3
1 A
FAST-BLOW
DIP 1
DIP 2
DIP 1
DIP 2
DIP 1
DIP 2
DIP 3
DIP 5
DIP 4
DIP 1
DIP 2
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
STEP-BY-STEP WITH STOP
STEP-BY-STEP
DEAD MAN
PRE-FLASHING
PHOTOCELL
DURING OPENING
SAFETY DEVICES TEST
CONDOMINIUM
• I Start pulse:
• II Start pulse:
• III Start pulse:
• IV Start pulse:
• I Start pulse:
• II Start pulse:
• III Start pulse:
• If Start button is held down:
• If Pedestrian button is held down OPT:
Enables pre-flashing of 2 seconds before motor activation during opening
and closing.
When the photocell is intercepted during both opening and closing, the
door/barrier motion is locked until the photocell is freed.
Subsequently, there is always an opening phase.
Enables the safety deviceS TEST before activating the opening and
closing cycle. The TEST consists of temporarily cutting the power to the
devices (+SAFETY 14 terminal ) checking correct switching of the contact
(SAFETY 6 terminal).
The cycle can only start if the devices work perfectly, if not, three prolon-
ged flashes indicate the fault.
Disables pre-flashing.
Disables the photocell function during opening.
Disables the safety devices test.
During opening it does not receive other Start commands after the first
one; during Pause subsequent Start commands reload the pause time.
• I
:
• Subsequent Start pulses:
Pause from opening limit switch
• Start pulse during pause:
• Subsequent Start pulse:
Start pulse
OPEN
STOP (will not reclose automatically)
CLOSE
OPEN
OPEN
CLOSE
OPEN
OPEN
CLOSE
OPEN
Uninfluential
Reloads the pause time (if dip 6 ON)
or CLOSES (if dip 6 OFF)
OPEN
The settings are stored during the rest phase (door/barrier closed).