spirit
level
2.4 install guides
guide clip
cushion head stop
bracket arm
G
15mm (nom.)
guide lead-in form
top door stop
45°
5mm
correct
bending of
S2 guide
lead-in
CAUTION: Restricted headroom installation is
not recommended for automated doors unless
the door is installed lower into the opening.
NOTE: This will reduce the drive through height.
2.4.1 positioning guides
2.4.2 creating proper guide lead-in
Fig: 2.4.1
Fig: 2.4.2
Fig: 2.4.3
a) Check that curtain overlaps equally on both sides.
b) Check that guides
C
are the correct length (marked G -
normal or restricted), that is, starts level with the brackets.
(Fig 2.4.1)
If guides need to be shortened cut from bottom
of guide.
c) Now position one guide over the edge of the door curtain.
Mark and drill the top fixed guide clip and secure using a
10mm (5/16”) coach screw and washer, allowing 3-4mm
clearance between the door and the inside of the guide.
d) Ensuring guide is plumb, using spirit level
(Fig 2.4.2)
, then
drill and fix remaining clips and head stop.
NOTE:
Welding of guides to steelwork is usually not
recommended
e) With the top of the 2nd guide level with the first, repeat (c)
and (d).
The shape of lead-in is critical for successful door operation
and trouble free performance. The shape of lead-in needs to
be formed by the installer, refer to
(fig 2.4.3)
.
a) With multigrips, bend top 5mm of lead-in approximately
45° to prevent Nylofelt
®
catching on lead-in.
b) Bend lead-in from door stop to top of lead-in (along press
cut), to finish 15mm from its original position.
c) Check top of guide lead-in to ensure that the door does
not make contact when rotated. Damage to Nylofelt
®
could result.
Installer may need to increase the 15mm
dimension for larger door heights to ensure the
smooth operation of the door.
dimension panel
Rec
o
m
m
e
n
ded
height (mm) width (mm)
G
up to 2400
up to 5500
0
2401-3300
up to 5500
0
3301-4200
up to 5500
0
4201-5100
up to 5500
0
Rest
ric
te
d
up to 2400
up to 5500
60
90*
2401-3300
up to 5500
40
60*
3301-4200
up to 5500
20
4201-5100
up to 5500
0
R2F has a maximum width of 5100mm.
*R2L Only, above 2400mm only available in WA
tip
WARNING! Do not grease the guides. Grease will
damage the Nylofelt
®
running strips and make
doors heavier to operate.
10
Roll-A-Door
®
Series 2 installation instructions