10. Door opens but won't close:

    Check the Safety Infra-red Beam (if you have 

installed this accessory). If the light is blinking, 
correct alignment.

    If opener light does not blink and it is a new 

installation, check the down force. Repeat the safety 
reverse test after the adjustment is complete.

11. Opener light does not turn on:

   Replace light bulb (40 Watts maximum). Replace 

burned out bulbs with rough service light bulbs.

12. Opener light does not turn off:

   There may be a defective earth at the ceiling or wall 

receptacle. The unit must be earthed.

13. Opener strains or reversed during opening:

   Door may be unbalanced or springs are broken. 

Close door and use manual release rope and handle 
to disconnect trolley. Open and close door manually. 
A properly balanced door will stay in any point of 
travel while being supported entirely by its springs. If 
it does not, call for professional garage door service 
to correct the problem. Do not change force settings.

14. Opener motor hums briefly then won't work:

• 

   Garage door springs are broken (see no. 13).

• 

   If problem occurs on first operation of opener, door is 

locked. Disable door lock. If chain was removed and 
reinstalled, the motor may be out of phase. Remove 
chain; cycle motor to down position. Observe drive 
sprocket. When it turns in clockwise direction and 
stops in down position, re-install chain. Repeat safety 
reverse test after adjustment is complete.

15. Opener won't activate due to power failure:

• 

   Pull manual release rope and handle down and 

back to disconnect trolley. Door can be opened and 
closed manually. When the power is restored, pull the 
manual release handle straight down. The next time 
the opener is activated, the trolley will reconnect.

    The Emergency Key Release accessory (if fitted) 

disconnects the trolley from outside the garage in 
case of power failure.