Operating Controls
01.
02.
03.
04.
05.
06.
07.
08.
09.
10.
11.
12.
13.
PROG InPUT
is used to connect the Universal Handheld Programmer to edit control and receiver functions.
Safety Infra-red Beam Auto-Close Shunt
has to be placed on to enable the Auto-Close feature.
Terminal Block:
PWR
is used to power devices such as Safety Infra-red Beams and external receiver (100 milliamp max).
IR
input is used to connect to Safety Infra-red Beam.
IR(0V)
is a 0 volt connection for Safety Infra-red Beam.
COM
is a common -ve ground for accessories.
OSC
is used for the connection of a wired switch (momentary contact). This switch can then be used to open, stop or
close the door. Install the wall switch in a location where the switch is out of reach of children and the garage door is
visible.
AUX
allows the opener to operate other devices such as external lights, or an alarm system.
OPen lIMIT leD (Green)
is used during installation to help set the open limit position. It also illuminates and flashes
as the door opens, and remains on when the open limit position has been reached.
ClOSe lIMIT leD (Red)
is used during installation to help set the close limit position. It also illuminates and flashes as
the door closes, and remains on when the close limit position has been reached.
DATUM ADjUST SCReW
is used during installation to set mid point of the door’s travel.
MInUS (-) button (Red)
is used during installation to set the close limit position. Pressing and holding this button will
move the door in the close direction. Movement stops when the button is released. This button is also used for storing
or erasing the transmitter button you wish to use to command the door to open, stop or close.
NOTE: The safety obstruction system is inoperable whenever the MINUS (-) button is used to move the door.
CODe SeT leD (Red)
flashes when a transmitter button is stored.
lIMIT SeT button (White)
is used during installation, together with the PLUS (+) and MINUS (-) buttons, to set the door
limit positions. The LIMIT SET button is also used to re-initialise the opener.
SeRVICe leD (Yellow)
indicates when the opener requires service or repairs, and is used in conjunction with the datum
screw during installation.
OPeRATe button (Blue)
is used during installation to test the open, stop and close cycles for the opener. The opener
has to be initialised by the LIMIT SET button to make the OPERATE button operable.
fORCe MARGIn SeT button
. The obstruction force margin is set automatically during installation. The margin can
be adjusted manually using the FORCE MARGIN SET button (White). Holding the FORCE MARGIN SET button and
pressing PLUS (+) or MINUS (-) buttons will increase or decrease the amount of force. The FORCE MARGIN SET button
should only be used if environmental factors, such as high winds, affect the door’s operation.
PlUS (+) button (Green)
is used during installation to help set the open limit position. Pressing and holding this button
will move the door in the open direction. Movement stops when the button is released.
NOTE: The safety obstruction system is inoperable whenever the PLUS (+) button is used to move the door.
Controll-A-Door
®
P
Instruction Manual
6