fig. 27
Step 15.3 - Set the Open limit Position
Press and hold the PLUS (+) button until the door
reaches the desired open limit position. Single presses
of the button will inch the door closed
(fig. 27)
.
IMPORTAnT WARnInG:
The door will
automatically close, open and close again
once Step 15.3(b) is performed
. Ensure that
no persons or objects are in the door’s path.
Press the LIMIT SET button to store the close position
into memory
(fig. 27)
.
The door will now automatically close and open to the
safety obstruction settings profile. Please be aware of
the above warning.
The opener can now be operated with the OPERATE
button.
Step 15.4 - Resetting the Door limit Positions
The door limit positions can be deleted for new positions
using the steps below.
Press and hold the CLOSE button for six (6) seconds
until you hear three beeps and the CLOSE LIMIT LED
starts to flash.
Release the CLOSE button.
Follow Steps 15.1 to 15.3 to set new travel limit
positions.
a.
a.
b.
a.
b.
c.
Setting Travel limits
Controll-A-Door
®
P
Instruction Manual
16