32
the number of network packets, but increase the amount of time to receive
characters. Smaller values may increase the number of network packets, but
decrease the amount of time to receive characters. The range is 1 through 65535.
IP ADDRESS
Software or hardware attempting to access the serial server via the network must
know the
IP Address
of the server. In DHCP mode (factory default), the serial server
requests and receives a dynamic IP address from a DHCP server when it first
connects to the network. If there is not a DHCP Server on your network, this device
will automatically default to IP Address
169.254.102.39
. If the serial server is unable
to connect to your network using this address, there are two methods to manually
configure the IP Address.
1.
Method One: Change your PC Network to Match the Serial Server
a.
Open the network connection on your PC
b.
Click on Internet Protocol (TCP/IP) and click <Properties>.
Change the parameters to the following:
IP Address = 169.254.102.1
Subnet Mask = 255.255.255.0
Default Gateway = 169.254.102.100