CONNECTING  VESR9XX SERIAL SERVERS TO A NETWORK 

NETWORK CONNECTION (10BASET/100BASETX) 

When connecting a serial server equipped with a 10BaseT/100BaseTX network 

connection 

(RJ45 connector) a standard network cable is connected from the serial 

server to a network drop. PCs configuring and/or communicating with the serial 

server are also connected to the network.  

FIBER OPTIC CONNECTION 

When connecting a serial server equipped with a fiber optic interface to a fiber 

optic link 

the appropriate fiber optic cable must be connected between the serial 

server and the network interface. Refer to the List of VESR9xx Serial Server Models at 

the beginning of this manual for a list of supported fiber types, distances and 

connectors. 
 

Ethernet Pass-through Port 

VESR92x serial servers are configured with an additional RJ45 network port. This port 

can be used to connect additional Ethernet devices, such as a local workstation, to 

the network.  
 
 
 
 
 
 

Ethernet Pass-through Port

 

Содержание VESR901

Страница 1: ...VESR9xx Serial servers...

Страница 2: ...wa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Website www bb smartworx com support bb smartworx com European Headquarters B B SmartWorx Westlink Commercial Park Oranmore Co Galway Irelan...

Страница 3: ...POWER SUPPLY 17 CONNECTING VESR9XX SERIAL SERVERS TO SERIAL DEVICES 18 CONNECTING THE VESR901 X 19 CONNECTING THE VESR902T X 19 CONNECTING THE VESR902D X 20 CONNECTING VESR9XX SERIAL SERVERS TO A NETW...

Страница 4: ...E 35 PASSWORD 36 SERIAL INTERFACE MODES 36 SERIAL SERVER NAME 37 SERVER SERIAL PORT NUMBER 37 SERIAL WATCHDOG 37 SUBNET MASK 37 TCP TRANSMISSION CONTROL PROTOCOL 38 UDP USER DATAGRAM PROTOCOL 38 VCOM...

Страница 5: ...x C Dimensional Diagrams 51 APPENDIX D CONNECTOR PINOUTS 55 VESR901 VESR921 SERIES 55 VESR902D SERIES 57 VESR902T VESR922T SERIES 58 STANDARD ETHERNET CABLE RJ 45 PIN OUT 59 B B SMARTWORX TECHNICAL SU...

Страница 6: ...ode on the network The serial ports can be accessed over a LAN WAN using Direct IP Mode Virtual COM Port or Paired Mode connections VESR9xx Serial Servers feature 10BaseT or 100BaseTX copper network m...

Страница 7: ...available with one or two serial connections and one or two Ethernet connections Network connection options include 10BaseT 100BaseTX copper or several different fiber optic options on models with a...

Страница 8: ...N FIBER ST 80KM VESR902T Vlinx 2PORT TB ESS DIN CU ETHERNET VESR902T SC Vlinx 2PORT TB ESS DIN FIBER SC VESR902T SC40 Vlinx 2PORT TB ESS DIN FIBER SC 40KM VESR902T SC80 Vlinx 2PORT TB ESS DIN FIBER SC...

Страница 9: ...SC CU VESR922T MT VLINX 2PORT TB ESS DIN FIBER MULTI ST CU VESR922T SC VLINX 2PORT TB ESS DIN FIBER SC CU VESR922T SC40 VLINX 2PORT TB ESS DIN FIBER SC 40KM CU VESR922T SC80 VLINX 2PORT TB ESS DIN FI...

Страница 10: ...de voltage range 10 100 Mbps Ethernet with Auto Selection LAN and WAN Communications TCP Client or Server or UDP operation configurable Virtual COM port and Paired Mode capabilities Firmware Upload fo...

Страница 11: ...ors and a recessed Mode switch PACKAGE CHECKLIST VESR9xx Serial Servers are shipped with the following items included VESR9xx Serial Server Module Quick Start Guide VESR9XX SERIAL SERVER ENCLOSURES AN...

Страница 12: ...D The Ready LED green blinks once per second if the system is operating correctly If the LED is off it indicates the system is not operating correctly SERIAL PORT LEDS VESR901 x serial servers feature...

Страница 13: ...ly If the LED is off it indicates the system is not operating correctly Serial Port LEDs VESR921 x serial servers feature one serial port VESR922x serial servers feature two serial ports Each serial p...

Страница 14: ...r models using 10BaseT 100BaseTX network connections use an RJ45 receptacle The serial server is connected to a standard Ethernet network drop using a straight through RJ45 male Ethernet cable VESR92x...

Страница 15: ...on the model VESR901 x serial servers feature one serial port and use a DB 9M connector for RS 232 and a five position removable terminal block for RS 422 and RS 485 connections VESR902D x serial ser...

Страница 16: ...16 Five Position Pluggable Terminal Blocks Note Refer to Appendix D for connection pin outs POWER CONNECTOR The power connector is a 5 08 mm 2 position pluggable terminal block Power Connection...

Страница 17: ...Note In this section devices to be connected to the serial server s serial connection are simply referred to as the serial device CONNECTING THE POWER SUPPLY Connect a DC power supply to the power ter...

Страница 18: ...ve to the A line in the idle mark state Ground provides a common mode reference RS 485 connections support 2 wire or 4 wire operation When configured for 4 wire operation the connection supports two s...

Страница 19: ...through cable If you select RS 422 mode RS 485 2 wire mode or RS 485 4 wire mode when you configure the serial server you must connect the serial device appropriately via the 5 position terminal block...

Страница 20: ...has two connectors both of which are DB 9M connectors You must connect the serial device to the serial server via a serial cable The VESR902D is a DTE If the serial device is a DTE use a null modem cr...

Страница 21: ...CTION When connecting a serial server equipped with a fiber optic interface to a fiber optic link the appropriate fiber optic cable must be connected between the serial server and the network interfac...

Страница 22: ...can be used CONFIGURING WITH VLINX MANAGER VESR9xx Serial Servers can be configured over the network Vlinx Manager software running on a PC To open Vlinx Manager From the Desktop click Start Programs...

Страница 23: ...bar type the IP address of the serial server Note Your serial server comes from the factory pre configured to receive an IP address from a DHCP Server If DHCP assignment is not available it will defa...

Страница 24: ...n Console Mode when On the VESR901 Port 1 LED is On and the Ready LED is Off On VESR902x models Port 1 LED is On and the Port 2 LED is Off To configure the serial server open the Vlinx Manager softwar...

Страница 25: ...ed in previous sections Configure the serial server with the appropriate network settings using Vlinx Manager or the web interface Configure your software application with the appropriate IP address a...

Страница 26: ...AL SERVERS IN PAIRED MODE When using serial servers in Paired Mode two serial servers connected to serial devices via their serial ports are connected to the network The serial devices communicate dir...

Страница 27: ...to their normal states when the device resumes normal operation RELOADING FACTORY DEFAULTS To reload Factory Defaults press and hold the Mode switch for more than 10 seconds The LED indicators respond...

Страница 28: ...ers to buffer before sending the characters to the network Larger values decrease the number of network packets but increase the amount of time to receive characters Smaller values increase the number...

Страница 29: ...is selected which is rare The 2 stop bits setting is only valid when 6 7 or 8 data bits is selected DEFAULT GATEWAY The Default Gateway address sets the default route to remote networks enabling users...

Страница 30: ...ected When the end delimiter is received the buffered characters including the start and end delimiters are sent to the network When Delimiter Removal is enabled it removes the delimiter character s b...

Страница 31: ...clude No Flow Control Hardware Flow Control RTS CTS and Software Flow Control XON XOFF The Flow Control setting must match the requirements of the serial device connected Note Select No Flow Control w...

Страница 32: ...eives a dynamic IP address from a DHCP server when it first connects to the network If there is not a DHCP Server on your network this device will automatically default to IP Address 169 254 102 39 If...

Страница 33: ...baud 8 data bits and 1 stop bit c Enter Console Mode Press and hold the serial server s RESET SWITCH for 2 to 10 seconds The LED indicators will respond as follows MODEL PORT 1 LED PORT 2 LED READY L...

Страница 34: ...od to connect to the serial server l LINK STATUS Link Status of the currently selected serial server is shown on the Login page of Vlinx Manager Link status indicates the type of Ethernet connection b...

Страница 35: ...d Mode is also called SERIAL TUNNELING Serial devices connected to serial servers on each end of the link can communicate as it they were connected by a serial cable For Paired Mode to work one serial...

Страница 36: ...systems Capable of baud rates up to 115 2 kbaud over short distances typically 50 feet Typically uses DB 9 connectors but terminals are also used on VESR9xx serial servers RS 422 Point to point commu...

Страница 37: ...902D x and VESR902T x serial servers feature two serial ports SERIAL WATCHDOG Serial Watchdog controls the duration of serial inactivity when the serial port is determined idle and causes all connecti...

Страница 38: ...hen the serial server is configured as a TCP server it waits for connections to be initiated by another network device You must set up the TCP port number that it will listen to for connections and se...

Страница 39: ...municates over the network with a PC acting as a remote COM port for the computer Both the serial server and the computer must be configured for VCOM operation Virtual COM ports can be set up on the P...

Страница 40: ...compatible with the selected serial server is available in this list To download the latest firmware files from the Internet 1 Go to the Tech Support tab on the B B SmartWorx web site http www bb ele...

Страница 41: ...progress of the transfer In the Firmware File drop down list select the firmware file to upload to the serial server Click Upgrade The Progress box and Progress bar display information on the upgradi...

Страница 42: ...to check the operation of connected serial servers and VCOM ports on the local computer The Computer Information box displays information about the type of network connections the IP addresses Subnet...

Страница 43: ...ox appears Select the option a serial server In the drop down box select the specific serial server you want to check Click the Start button Information about the progress of the pinging process is di...

Страница 44: ...agnostics dialog box appears Select the option a virtual communications port In the drop down box select the specific COM port you want to check Click the Start button Information about the progress o...

Страница 45: ...5 0 Gateway 169 254 102 100 MAC Address Fixed see bottom label Firmware Version X X X Current Version Hardware Version X X Current Version Port 1 2 Serial port mode RS 232 Baud Rate 9600 Data bits 8 P...

Страница 46: ...ction Using a standard web browser such as Internet Explorer 6 0 7 0 or Firefox 1 5 2 0 Software Vlinx Manager for serial server configuration Windows 2000 XP 32 64 bit 2003 Server 32 64 bit Vista 32...

Страница 47: ...ion VESR90x 4 0W max VESR92x 6 0W max Terminal Blocks Wire Size 28 to 16 AWG Wire Type Copper Wire Only Tightening Torque 5 KG CM Wire Temp Rating 105 C Minimum Sized for 60 C Ampacity Note One Conduc...

Страница 48: ...one per port Color Green On Port open Blink Data traffic Link LED VESR 90x E1 E2 LED VER92x Color Green On 100BaseTX Off 10BaseT Blink Data traffic Ready LED Color Green Blink once per second System O...

Страница 49: ...D RS 485 lines 4 wire TXDA TXDB RXDA RXDB GND Baud Rates 75 150 300 600 1200 2400 4800 7200 9600 14400 19200 28800 38400 57600 115200 230400 Data Bits 5 6 7 8 Parity None even odd mark space Stop bits...

Страница 50: ...efinable UDP Unicast or Multicast Connection Modes Server Client VCOM Paired Client Connection At power up or upon data arrival Search Serial direct COM and Ethernet autosearch or specific IP Diagnost...

Страница 51: ...51 APPENDIX C DIMENSIONAL DIAGRAMS Dimensional Diagram of a VESR901 Serial Server...

Страница 52: ...52 Dimensional Diagram of a VESR902D Serial Server...

Страница 53: ...53 Dimensional Diagram of a VESR902T Serial Server...

Страница 54: ...54 Dimensional Diagram of a VERR92x Serial Server...

Страница 55: ...55 APPENDIX D CONNECTOR PINOUTS VESR901 VESR921 SERIES DB9 M Pin Direction RS 232 1 Input DCD 2 Input RXD 3 Output TXD 4 Output DTR 5 GND 6 Input DSR 7 Output RTS 8 Input CTS 9 Input RI...

Страница 56: ...56 Terminal RS 422 485 4 Wire RS 485 2 Wire A TDA Data A B TDB Data B C RDA D RDB E GND GND...

Страница 57: ...SERIES DB 9M Pin RS 232 Direction RS 232 RS 422 485 4 Wire RS 485 2 Wire 1 DCD Input RDA 2 RD Input RDB 3 TD Output TDB Data A 4 DTR Output TDA Data B 5 GND GND GND 6 DSR Input 7 RTS Output 8 CTS Inpu...

Страница 58: ...ut RDA D RD Input RDB E GND GND GND In the RS 422 mode TX lines are outputs and RX lines are inputs Connect the serial server TXB line to the RXB line of the serial device and the serial server TXA to...

Страница 59: ...ERNET CABLE RJ 45 PIN OUT RJ 45 Pin Signal Wire Color RJ 45 Pin 1 TX White Green 1 2 TX Green 2 3 RX White Orange 3 4 Not used Blue 4 5 Not used White Blue 5 6 RX Orange 6 7 Not used White Brown 7 8 N...