Calibration Lock
The BB-200 indicators have a switch on the motherboard that prevents you from entering calibration
mode, as shown in the image below. This is so that the housing of the indicator can be sealed,
preventing unauthorized access to the calibration menus. Before you can calibrate the scale, you must
disable the calibration lock.
TIP
By default, the BB-200 usually ships with the Calibration Lock
UNLOCKED. There is usually no need to remove all the screws and open
the back of the indicator to flip the switch.
If you see “C1” when you enter programming mode (below), you’re good
to go. If you see “C9,” you need to open the indicator and flip the switch.
Location of the Calibration Lock Switch
Entering Calibration Mode
Turn the indicator on and make sure it is connected to the scale. Ensure that the scale is reasonably level
and clear of any debris.
Press
and
simultaneously for two seconds, then release. The display will read “C01.” If
the display reads “C09,” the Calibration Lock is engaged. See the previous section to unlock it.
C01 is the first of 49 menus, each of which has various different settings that you can adjust. C01
through C08 are the calibration menus.
Navigating the Calibration and Programming Menus
The menus take the format of Cnn, where nn is the menu number. When you first navigate to a menu,
the indicator displays the menu number only. Press the
key to enter the menu and the current
numeric value of that menu will be displayed. Use the arrow keys shown in the table below to change
the menu values.