BB-200 Weighing Indicator – Programming and User’s Manual
Copyright © 2023 – B and B Scales, Inc. All Rights Reserved.
Page 12
C33
=
0
No output
none
C33
=
1
Weight
comparison
Hi OK Low Zero
C33
=
2
Stable weight
comparison
Hi OK Low Zero
C33
=
3
Set point output
Set point 1 Set point 2
Table 4:
Checkweigh Port Settings
Output port
output condition
definition
C33
=
1
C33
=
2
OUT1
weight>=C13
Hi (over)
OUT2
C13> weight >=C14
OK (accept)
OUT3
weight<C14
Low (under)
OUT4
weight <20d
Zero
Table 5:
Setpoint Port Settings
Output port
output condition
definition
C33
=
3
OUT1
weight >=C14
Set point 1
OUT2
weight >=C13
Set point 2
For example, for a check weight application, connect the indicator with three lights; yellow, green, and
red. The yellow light comes on when the scale is overloaded, the green light comes on if the seight is in
the “OK” range, and the red light comes on if the weight is underweight.
Table 6:
DB9 Pin Settings