0x08 (8d)
Write
-
(Special)
-
-
*Firmware version in which command and parameter options were first supported.
Zlinx Command Descriptions
Command descriptions in this section are listed alphabetically. Command categories
are designated within “< >” symbols that follow each command title. Zlinx Modules
expect parameter numerical values in hexadecimal (designated by the “0x” prefix).
AM (Auto-set MY) Command
<Networking & Security> AM
Command is used to
automatically set the MY
(Source Address) parameter from the factory-set module serial number. The address
is formed with bits 29, 28 and 13-0 of the serial number (in that order).
AT (Guard Time After)
Command
<Command Mode Options> AT
Command is used to set the DI
time-of-silence that follows the
AT command sequence
character (CC Command).
By default, AT Command Mode
will activate after one second of
silence.
Refer to the AT Commands section to view the default AT Command Mode
Sequence.
BD (Interface Data Rate) Command
NOTE: AT Commands issued without a parameter value will return the currently
stored parameter.
AT Command: ATAM
Binary Command: 0x3A (58 decimal)
Minimum firmware version required: 4.40
Binary Command: 0x05 (5 decimal)
Parameter
Range:
0x02 – 0xFFFF [x 100
milliseconds]
Number of bytes returned: 2
Default Parameter Value: 0x0A (10
decimal)
Related Commands: BT (Guard Time
Before), CC (Command Sequence
Character)