4.3 Turning ON / OFF The Timer To Close
With the unit powered down and the gate
in the closed position, locate the supplied
3 button control station and do the
following (in order):
1.
Press and hold the STOP button
2.
While holding the STOP button,
press and hold the CLOSE
button.
3.
While holding the STOP and
CLOSE buttons, press and
release the OPEN button.
4.
Release the CLOSE button, then
the STOP button.
5.
Trigger the open limit switch. If
the timer is on, you will see the
screen to the left.
6.
Repeat step 1 to toggle the timer
off
NOTE: The AutoClose screen will not be
visible if the timer is turned off
There is a 3 minute window with which
to turn the timer to close on or off each
time the operator power is turned on
.
4.4 Setting The Timer To Close
1.
From the main menu, select ‘Set
Param’.
2.
Use the UP arrow to scroll to the
AUTO CLS screen and press OK.
3.
Press OK again to activate cursor.
Use the arrow keys to set the desired
time.
4.
Press OK to save
Note: s = seconds, m = minutes, h =
hours
AutoClose
Activated
00:00s
00:00s
Bottom number
shows elapsed
time.
CLOSE
OPEN
STOP
AutoCLS
T =20:00s
Ta = 00:00
Bottom number shows
elapsed time.