2.2.7  Make the final concrete pour, again making sure the axle height does not 

change and remain level and plumb. Remove any concrete that might have 
splattered inside the exposed conduits.  

2.2.8  After the concrete has set, install the roller wheels, collars and nuts onto the 

axles if not previously installed.  Place two collars (spacers) on each side of 
the shaft, then the wheel, then another collar, and finally the nut.  Adjust the 
wheels and axle nuts so there is no side play in the wheels, but yet they can 
still be turned easily by hand. Tighten set screw on the nut.  Grease the wheel 
bearings using the grease fittings. The wheels may be pre-greased.  Be 
careful not to over-grease the bearings. 

NOTE: It is critical that the axle nuts are secure prior to the gate beam 

installation. 

2.2.9  Install the four guide wheels into the guide wheel receivers on the wheel 

stanchion.  Leave the bolts fully backed off to allow the guide wheels to 
insert completely into the receivers. 

2.4  Installing the Gate and Motor Components   

Perform the following steps to install the gate (gate leaf), motor, and limit switches on the 
motor/main stanchion.   

2.4.1  Lift the gate assembly using a crane or forklift. Guide the gate onto the first 

set of roller wheels, with the wheels fitting between the I-beam and the 
channel.  Push the gate onto the second set of roller wheels.   

2.4.2  Move the gate by hand to the halfway position. Install the end plates and 

rubber stops onto the ends of the gate. 

2.4.3  Slide the gate through about ⅔ of its travel. If the gate binds, adjust the guide 

roller wheels to eliminate the binding. 

2.4.4  Mount the motor and gear assembly. Mount the motor on the wheel post 

closest to the roadway opening and on the side between the two single posts.    
Leave the motor mount in the down position with the bolts slightly loose 
until the motor rotation and limit switches have been tested. 

2.4.5  Mount the limit switches. 

Содержание 4X0E Series

Страница 1: ...ICLE BARRIER INSTALLATION MANUAL B B ARMR Headquarters Tech Support 5900 S Lake Forest Dr Suite 230 McKinney TX 75070 Phone 800 367 0387 Fax 972 385 9887 E mail info bb armr com techsupport bb armr co...

Страница 2: ...upport via telephone and possible on site support with advanced scheduling Safety Your safety is important to us If you have any questions or are in doubt about any aspect of the equipment please cont...

Страница 3: ...our vehicle barrier or if we can help you with any other facility security issues please contact us directly at HQ Tech Support B B ARMR 5900 S Lake Forest Dr Suite 230 McKinney TX 75070 Phone 800 367...

Страница 4: ...ents 11 2 5 Control System Installation 12 3 4 Operational Test 15 3 5 ECO Operation 15 3 6 Barrier Operation during a Power Outage 15 3 7 Barrier Operation during a Power Outage With Optional Manual...

Страница 5: ...n be purchased at the time of order to allow gate opening and closing without disengaging drive assembly Motor controller ramps up and down the movement of the gate to reduce wear and shock on drive u...

Страница 6: ...adway and Security Solutions 0400E 9001 Rev J 1 1 2 Drive Stanchion The drive stanchion supports the gate with the four main drive wheels and allows the drive unit to mesh with the rack located on the...

Страница 7: ...electrically actuated to lock the gate closed Limit switches indicate the location of the lock pins The actuator motor 2 wires and its two limit switches 2 wires each may share a conduit to the elect...

Страница 8: ...ior to the gate beam installation 2 2 3 The center of the axles must be 31 inches above the roadbed height at the roadbed s highest point If wheels are factory installed make sure the tops of the whee...

Страница 9: ...nstall the four guide wheels into the guide wheel receivers on the wheel stanchion Leave the bolts fully backed off to allow the guide wheels to insert completely into the receivers 2 4 Installing the...

Страница 10: ...he motor assembly 2 5 Control System Installation The electrical control enclosure is mounted on the main stanchion 2 5 1 Install power wires to breaker inside external enclosure mounted to control bo...

Страница 11: ...OR Q8 RED INDICATOR Q9 ECO Q10 OPTIONAL DEVICES Loop Detector One loop detector and socket come pre wired for use as a safety The loop wires connect to terminals 7 8 on the loop detector socket The sa...

Страница 12: ...ult value is 8 seconds During a malfunction the lock pins will reverse to a retracted position and the RED INDICATOR output will flash rapidly Investigation and adjustment of the trip plates and beam...

Страница 13: ...econd close limit switch is tripped the lock pin will engage Model 450 3 4 3 Verify that there are no interferences between the moving parts and that the limit switches are hitting the trip plates cor...

Страница 14: ...rated cordless drill 3 Access keys codes to Receiver Stanchion Locking Pin Access Door Receiver Stanchion Crash Pin Release 1 Open Crash Pin locking equipment access door 1 located on the top of the R...

Страница 15: ...Installation and Operations Manual Model 400E Series 17 B B ARMR A Division of B B Roadway and Security Solutions 0400E 9001 Rev J...

Страница 16: ...prevent accidental operation of the motor if power resumes during the use of the Manual Override Tool Do not position any part of your body in the pathway of moving 1 Locate the electric Drive Motor u...

Страница 17: ...nd LOCK PIN UP input is activated on the PLC 8 Manually open the gate by to see if the problem is mechanical or electrical If mechanical check for binding on the gate Gate makes noise during operation...

Страница 18: ...ecurity Solutions 0400E 9001 Rev J 6 REFERENCE DRAWINGS The following drawings are provided for reference only For job specific drawings and details please refer to the Submittal Documentation specifi...

Страница 19: ...odel 400E Series 21 B B ARMR A Division of B B Roadway and Security Solutions 0400E 9001 Rev J B B ARMR 2009 Chenault Dr 114 Carrollton Tx 75006 800 367 0387 GENERIC 400 CANTILEVER SLIDING GATE 20 RIG...

Страница 20: ...Operations Manual Model 400E Series 22 B B ARMR A Division of B B Roadway and Security Solutions 0400E 9001 Rev J B B ARMR 2009 Chenault Dr 114 Carrollton Tx 75006 800 367 0387 400 CRASH BEAM LEFT HA...

Страница 21: ...ns Manual Model 400E Series 23 B B ARMR A Division of B B Roadway and Security Solutions 0400E 9001 Rev J B B ARMR 2009 Chenault Dr 114 Carrollton Tx 75006 800 367 0387 450A CANTILEVER SLIDING GATE 20...

Страница 22: ...rations Manual Model 400E Series 24 B B ARMR A Division of B B Roadway and Security Solutions 0400E 9001 Rev J 400 SERIES CANTILEVER SLIDING GATE FOUNDATIONS B B ARMR 2009 Chenault Dr 114 Carrollton T...

Страница 23: ...Installation and Operations Manual Model 400E Series 25 B B ARMR A Division of B B Roadway and Security Solutions 0400E 9001 Rev J TYPICAL ELECTRICAL 450E SHOWN...

Страница 24: ...ted to unauthorized repairs improper installation installation not performed by BBRSS authorized personnel incoming supply power is outside the tolerance for the product failure to perform manufacture...

Отзывы: