IT1000-C / IT2000-C
1/4” IT
Tool
www.BAND-IT-IDEX.com
Document # P49050 Rev. C
© Copyright
BAND-IT-IDEX, Inc. 2015
All rights reserved
Page 27 of 36
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
F: 1-800-624-3925
Operating
Manual
The tool has components that must be checked and/or replaced on a regular schedule. If
tools are experiencing difficulties during function or there are audible air leaks coming from
inside the handle, the tool should be returned to BAND-IT for service. Pneumatic components
must be serviced by BAND-IT in order to assure proper tool performance after a repair.
Some applications and environments may require maintenance intervals to be adjusted.
Consult BAND-IT-IDEX for more information.
Preventative Maintenance
For best performance and to extend tool life:
• Follow preventative maintenance and parts replacement instructions at appropriate service
intervals.
• Do not remove factory applied lubrication from inside tool unless performing a thorough
maintenance procedure and then replacing with fresh lubricant immediately.
• Do not use degreaser in the tool body.
• Do not spray any lubricant or cleaner into the Quick Connect Air Couplings.
• Use nominal recommended tension setting (see “Air System Settings” page). Tension
pressures above the specified settings may cause premature clamp failure and/or tool wear.
• For maintenance beyond what is described in this manual, consult BAND-IT-IDEX Customer
Service at 1-800-525-0758 or 303-320-4555.
Clamps
Installed
Maintenance
Item
Maintenance
Action
Every 25,000
Maintenance Cover (pg. 29)
Clean & Re-Lubricate
Tension Block and Gripper (pg. 30)
Inspect, Clean, Re-Lubricate
Front Gripper (pg. 31)
Clean & Re-Lubricate
Cutter Blade & Blade Screws (pg. 31)
Inspect & Replace if necessary
Every 50,000
Tool Cavity, Tool Head, Linkages (pg. 34)
Clean & Re-Lubricate
Knife and Dimple Punch (pg. 33)
Inspect & Replace if necessary
Every 100,000
Head Pin and Front Cutoff Lever (pg. 32)
Inspect & Replace if necessary