- 21 -
This function transform the costa (PSD) contact in a second contact for photocells enabled also during the
opening phase.This option can be used when installing two pairs of photocells, one pair working only
during the closing phase and the second pair working during the closing and the opening
phase.Furthermore during closure if there is an obstacle between the second pair of photocells the control
board will stop the gate and then reverse the movement only when the obstacle is removed.
Values goes from 0 to 1
0 = function OFF
1= function ON
1. Press P1 and P2 simultaneously for three seconds
to begin programming the board.
2. Letter A appear on the display. Scroll the menu with P1
until letter F appears on the display.
Press P2 to confirm.
3. You should see 1 on the display. Scroll the values
with P1 until 4 will appear on the display.
Press P2 to confirm.
4. Select the value from 0 to 1 with P1
and press P2 to confirm.
ATTENTION!!!!!! The control board has a default setting of 0 = function OFF.
Parameter F4: transform pressure safety device contact in second photocell contact
If there is the need of a pushbutton for the pedestrian opening set this option to ON, and connect the push-
button to the “open” contacts.
Values goes from 0 to 1
0 = function OFF
1= function ON
1. Press P1 and P2 simultaneously for three seconds
to begin programming the board.
2. Letter A appear on the display. Scroll the menu with P1
until letter F appears on the display.
Press P2 to confirm.
3. You should see 1 on the display. Scroll the values
with P1 until 5 will appear on the display.
Press P2 to confirm.
4. Select the value from 0 to 1 with P1
and press P2 to confirm.
ATTENTION!!!!!! The control board has a default setting of 0 = function OFF.
Parameter F5: transform the “open” contact in “pedestrian open” contact