Section 6: Troubleshooting and Maintenance
Bambi MAX Service Manual
– Models HL4000-HL9800 23
IVC Sensor Adjustment
If the Bambi MAX valve is inoperable with a flashing red light on the indicator, follow this adjustment
procedure to reposition the IVC sensors:
1.
Loosen the two bolts holding the IVC to the top plate.
Do not fully remove the bolts.
2.
Move the IVC away from the cam.
3.
Place a 0.030” feeler gauge between the IVC sensors
and cam.
Feeler Gauge
IVC
Cam