Section 6: Troubleshooting and Maintenance
Bambi MAX Service Manual
– Models HL4000-HL9800 21
Section 6: Troubleshooting and Maintenance
Troubleshooting
Valve Troubleshooting
Problem
Status Lamp
Possible Cause
Solution
No power
○
Off
Circuit breaker tripped
Reset circuit breaker.
Aircraft / longline wiring
Check aircraft / longline wiring.
Valve Closed
Won’t Open
●
Yellow
No open signal
Check aircraft / longline wiring.
Controller failure
Contact service centre.
●
Green
Damaged drive cable
Replace drive cable.
☀
Flashing
Red
Sensor(s) out of adjustment
See page 25.
Valve Open
Won’t close
●
Green
Aircraft / longline wiring
Check bucket plug.
Check aircraft / longline wiring.
Controller failure
Contact service centre.
●
Yellow
Damaged drive cable
Replace drive cable.
☀
Flashing
Red
Sensor(s) out of adjustment
See page 25.
Valve Leaks
●
Yellow
Damaged seals
Replace seals.
Valve adjusted too high
Adjust valve down.
●
Red
Mechanical Jam
Clear jam / check linkage.
Long Dump
Time
●
Red
Valve adjusted too low
Adjust valve up.
Содержание MAX BBXHL4000
Страница 1: ...BAMBI MAX BUCKET Models HL4000 HL9800 SERVICE MANUAL 2023A ...
Страница 19: ...Section 3 Accessories Bambi MAX Service Manual Models HL4000 HL9800 14 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 66: ...Section 9 Specifications and Parts Bambi MAX Service Manual Models HL4000 HL9800 61 Suspension ...
Страница 68: ...Section 9 Specifications and Parts Bambi MAX Service Manual Models HL4000 HL9800 63 Bucket Shell ...
Страница 87: ...Section 10 Drawings Bambi MAX Service Manual Models HL4000 HL9800 82 Section 10 Drawings Pilot Controls ...
Страница 88: ...Section 10 Drawings Bambi MAX Service Manual Models HL4000 HL9800 83 Pilot Controls US Interagency ...
Страница 89: ...Section 10 Drawings Bambi MAX Service Manual Models HL4000 HL9800 84 Crew Controls External Power Supply ...
Страница 90: ...Section 10 Drawings Bambi MAX Service Manual Models HL4000 HL9800 85 THIS PAGE INTENTIONALLY LEFT BLANK ...