ELECTRICAL SUPPLY
• The equipment is electrically safe only when it is correctly connected to an effi cient ground connection carried out in accordance with
current safety regulations. It is necessary to check this essential safety requirement. If in doubt, call for a careful electrical check by a
qualifi ed technicians, since the manufacturer will not be liable for any damage caused by a poor ground connection.
• Have qualifi ed technicians check that the wiring is suitable for the maximum power absorption of the equipment, as indicated in the
technical plate, making sure in particular that the diameter of cables is suffi cient for the equipment’s power absorption.
• Adapters, multiple plugs and extension cables may not be used for the equipment’s power supply.
• An ominpolar switch in accordance with current safety regulations is required for the mains supply connection.
• The electrical supply to the burner must have neutral to ground connection. If the ionisation current has control with neutral not to
ground it is essential to make a connection between terminal 2 (neutral) and the ground for the RC circuit.
• The use of any components that use electricity means that certain fundamental rules have to followed, including the following:
- do not touch the equipment with parts of the body that are wet or damp or with damp feet
- do not pull on electrical cables
- do not leave the equipment exposed to atmospheric agents (such as rain or sun etc.) unless there is express provision for this.
- do not allow the equipment to be used by children or inexpert persons.
• The power supply cable for the equipment not must be replaced by the user. If the cable gets damaged, switch off the equipment, and
call only on qualifi ed technicians for its replacement.
• If you decide not to use the equipment for a while it is advisable to switch off the electrical power supply to all components in the system
that use electricity (pumps, burner, etc.).
GAS, LIGHT OIL, OR OTHER FUEL SUPPLIES
General warning notes
• Installation of the burner must be carried out by qualifi ed technicians and in compliance with current law and regulations, since incorrect
i
• Before installation it is advisable to carry out careful internal cleaning of all tubing for the fuel feed system to remove any residues that
could jeopardise the proper working of the burner.
• For fi rst start up of the equipment have qualifi ed technicians carry out the following checks:
• If you decide not to use the burner for a while, close the tap or taps that supply the fuel.
Special warning notes when using gas
• Have qualifi ed technicians check the following:
a) that the feed line and the train comply with current law and regulations.
b) that all the gas connections are properly sealed.
• Do not use the gas pipes to ground electrical equipment.
• Do not leave the equipment on when it is not in use and always close the gas tap.
• If the user of is away for some time, close the main gas feed tap to the burner.
• If you smell gas:
a) do not use any electrical switches, the telephone or any other object that could produce a spark;
b) immediately open doors and windows to create a current of air that will purify the room;
c) close the gas taps;
d) ask for the help of qualifi ed technicians.
• Do not block ventilation openings in the room where there is gas equipment or dangerous situations may arise with the build up of
toxic and explosive mixtures.
FLUES FOR HIGH EFFICIENCY BOILERS AND SIMILAR
It should be pointed out that high effi ciency boilers and similar discharge combustion products (fumes) at relatively low temperatures into the
fl ue. In the above situation, traditional fl ues (in terms of their diameter and heat insulation) may be suitable because the signifi cant cooling
of the combustion products in these permits temperatures to fall even below the condensation point. In a fl ue that works with condensation
there is soot at the point the exhaust reaches the atmosphere when burning light oil or heavy oil or the presence of condensate water
along the fl ue itself when gas is being burnt (methane, LPG, etc.). Flues connected to high effi ciency boilers and similar must therefore
be of a size (section and heat insulation) for the specifi c use to avoid such problems as those described above.
WARNING NOTES FOR THE USER HOW TO USE THE BURNER SAFELY