ENGLISH
20 / 42
0006160278_201804
ADJUSTMENTS
DISPLAY
The program continues in the minimum load position P1
DisplayLME71_024
DisplayLME71_025
(Rpm x 10)
To reduce the rpm value press
and
To increase the rpm value press
and
To confirm the modification in the internal memory and/or continue the adjustment sequence press
LME71 continues the sequence
DisplayLME71_026
(Operation)
DisplayLME71_027
(P1 minimum load %)
The program continues in the nominal load position P2
DisplayLME71_028
DisplayLME71_029
(Rpm x 10)
To reduce the rpm value press
and
To increase the rpm value press
and
To confirm the modification in the internal memory press
LME71 continues the sequence
DisplayLME71_030
(P2 nominal load %)
The program continues in the minimum load position P1
DisplayLME71_024
DisplayLME71_025
(Rpm x 10)
To exit the adjustment procedure press ESC
(press
and
at the same time),
the burners goes to operating position
DisplayLME71_027
(P1 minimum load %)
CAUTION / WARNINGS
It is recommended to save LME71 control unit settings also on PME71 board,
refer to the manual saving procedure for copying LME71 control unit parameters to PME71 board.
Содержание BPM 90 E 50kW
Страница 2: ......
Страница 43: ...ENGLISH 41 42 0006160278_201804 WIRING DIAGRAMS...
Страница 45: ......