User’s manual
power , not less than
Performance index at rated heating
power 30%, not less than
%
87,0
Heating circuit:
Rated heating effect
kWt
24,0
Rated heating power
kW
26,7
Rated gas consumption
M
3
/h
2,95/1,00
Temperature regulation range
o
С
30 ÷ 85
Operating water pressure
MPa
0,1 ÷ 0,2
Maximum water pressure
MPa
0,3
Volume of inserted expansion tank l
6,0
Air pressure in the expansion tank
MPa
0,1
Hot water supply circuit:
Rated heating effect
kWt
24,0
Rated input heating power, Qnom
KW
26,7
Rated gas consumption
m
3
/h
2,95/1,00
Water consumption at heating for
ΔT=25
o
С
l/min
14,0
Temperature regulation range
o
С
30 ÷ 60
Operating water pressure
MPa
0,02 ÷ 0,60
Minimal water pressure, Pmin
MPa
0,015
Maximum water pressure, Рmax
(at heat extension of water the
pressure must not exceed this
level)
MPa
1,0
Minimal water flow for switching
the boiler on
l/min
2,5
Minimal water flow for switching
the boiler off
l/min
1,5
Specific water consumption, D
dm3/min
11,6
Mass consumption of combustion
products
g/s
17,0/18,5
Average combustion products
temperature
o
С
120
Type of combustion products
output
Forced
Heat-transfer medium
Water
Water circulation type
Airtight forced circulation
Ignition type
Automatic ignition, electronic ignition
Maintenance of set temperature
Automatic maintenance with accuracy ±1 °С
Temperature indication
LCD display
Rated power tension
V
220 ±10%
Rated electric current frequency
Hz
50
Maximum electric power
consumption
kW
0,125
Safety fuse
А
2
Electrosecurity class
I
Protection rate
IP X4D
Overall dimensions: height widths
x depth
mm
720х410х326
Net/ Gross weight
kg
34,0 / 36,5
Connection dimensions:
Gas inlet
inch
G3/4
Heating circuit inlet and output
inch
G3/4
Hot water supply circuit inlet and
output
inch
G1/2
Inlet air orifice/ Output orifice for
combustion products (for coaxial
mm
Ø100 / Ø 60