Alternator #1 Temperature Threshold.

 

Controls the setpoint at which point field current is 

reduced when the the alternator temperature sensor indicates an over-temp condition at the alter-

nator. Requires temperature sensor installation. Preset at 108

˚

.

Absorption Voltage.

 

Controls the maximum limit of allowable bulk voltage. Starts at value set 

by battery program currently in use. Adjustment spans from 13.5 to 14.8 volts. To reverse direction 

of scroll, release magnet and wait for LED to display Av code. Re-activate switch with magnet and 

release when desired value is indicated.

Float Voltage.

 

Controls the maximum limit of allowable float voltage. Starts at value set by bat-

tery program currently in use. Adjustment spans from 13.0 to 13.8 volts. To reverse direction of 

scroll, release magnet and wait for LED to display Fv code. Re-activate switch with magnet and 

release when desired value is indicated.

Absorption Time.

 

Controls the minimum time period for non-calculated absorption charging. 

Standard  value  set  by  battery  program  selected. Adjustment  spans  in  tenths  of  hours  from  12 

minutes to six hours. To reverse direction of scroll, release magnet and wait for LED to display a1c 

code. Re-activate switch with magnet and release when desired value is indicated.

Float Time.

 

Controls the minimum time period for non-calculated float charging. Standard value 

set by battery program selected. Adjustment spans in tenths of hours from 12 minutes to six hours. 

To reverse direction of scroll, release magnet and wait for LED to display F1c code. Re-activate 

switch with magnet and release when desired value is indicated.

Field Threshold - Float To Absorption .

 

Controls the criteria the regulator uses to deter-

mine how hard the alternator has to be working to stay in calculated absorption charging mode. 

Factory set at 67% field output. Raising “ffl” shortens “ffl” increases calculated absorption charge 

time. Adjusted in 1% increments. Span of adjustment is 16% to 96%. To reverse direction of scroll, 

release “ffl” code. Reactivate switch with magnet and release when desired value is indicated.

Field Threshold - Bulk To Absorption .

 

Controls the criteria the regulator uses to determine 

how hard the alternator has to be working to stay in calculated bulk charging mode. Factory set 

at 67% field output. Raising “fba” shortens calculated bulk charge time. Lower ing “fba” increases 

calculated bulk charge time. Adjusted in 1% increments. Span of adjustment is 16% to 96%. To re-

verse direction of scroll, release magnet and wait for LED to display “fba” code. Re-activate switch 

with magnet and release when desired value is indicated.

Slope Voltage Correction.

 

Adjusts the voltage (in milivolts) the regulator uses when moni-

toring battery temperature sensing. Can be custom adjusted to meet the needs of unique battery 

technologies. Consult with battery manufacturer for specific slope voltage recommendations.

Battery #1 Temperature Threshold.

 

Controls the setpoint at which point field current is dis-

continued when the the battery temperature sensor indicates an over-temp condition at battery #1. 

Requires temperature sensor installation. Preset at 52°C.

Default Program Settings By Battery Type

UFP

FDC

GEL

AGM

OPS

FSB

HAL

START DELAY (SECS.)

1

1

1

1

1

1

1

SOFT RAMP (SECS.)

60

60

60

60

60

60

60

BULK VOLTAGE

14.1

14.6

14.1

14.38

14.6

14.4

14.0

BULK TIME (MINIMUM)

30 MIN

30 MIN

30 MIN

30 MIN

30 MIN

30 MIN

30 MIN

ABSORPTION VOLTS

13.9

14.4

13.9

14.18

14.4

14.2

13.8

ABSORPTION TIME (MINIMUM)

30 MIN

30 MIN

30 MIN

30 MIN

30 MIN

30 MIN

30 MIN

FLOAT VOLTS

13.4

13.4

13.7

13.4

13.4

13.4

13.5

FLOAT TIME (MINIMUM)

30 MIN

30 MIN

30 MIN

30 MIN

30 MIN

30 MIN

30 MIN

FLOAT TIME (MAXIMUM)

6 HRS.

6 HRS.

6 HRS.

6 HRS.

6 HRS.

6 HRS.

6 HRS.

HIGH VOLTAGE ALARM (VOLTS)

15.2

15.6

15.1

15.38

15.6

15.4

15.0

LOW VOLTAGE ALARM (VOLTS)

12.5

12.5

12.5

12.5

12.5

12.5

12.5

MAX BAT. TEMP.

125˚F/52˚C

125˚F/52˚C

125˚F/52˚C

125˚F/52˚C

125˚F/52˚C

125˚F/52˚C

125˚F/52˚C

MAX ALT. TEMP.

225˚F/107˚C

225˚F/107˚C

225˚F/107˚C

225˚F/107˚C

225˚F/107˚C

225˚F/107˚C

225˚F/107˚C

- 12 -

Bulk Time.

 

Controls the minimum time period for non-calculated bulk charging. Standard value 

set by battery program selected. Adjustment spans in tenths of hours from 12 minutes to six hours. 

To reverse direction of scroll, release magnet and wait for LED to display b1c code. Re-activate 

switch with magnet and release when desired value is indicated.

Содержание MAX CHARGE MC-612-DUAL

Страница 1: ...ternators are being used to charge the same large battery bank The MC 612 DUAL provides two field output connectors two power input connectors and two system ground connections making it pos sible to...

Страница 2: ...rom inverters transmitters and other sources of RF noise convenient access and readability of the display The regulator wiring harness is 54 inches long providing a three to four foot radius for mount...

Страница 3: ...BATTERY Temperature Sensor MC TS A Sensor lug connects to negative battery post enabling regula tor to monitor and respond to battery temperature condition USE CARE TO ENSURE POSITIVE AND NEGATIVE WI...

Страница 4: ...switch or to the wire in the existing engine wiring loom that delivers switched voltage from the ignition switch In some cases an oil pressure switch may be used to activate the regulator In either ca...

Страница 5: ...e 1 4 spade terminal from the terminal 12 pin Crimp the spade terminal to the sense wire and reconnect the spade to the 12 terminal pin Data TX and RX Terminals 13 and 14 Are currently for factory use...

Страница 6: ...gramming features Included with the regulator is a small screwdriver that doubles as the regulator s programming tool A small magnet embedded in the tip of the screwdriver s handle allows the user to...

Страница 7: ...ds the bulk charge time by an additional six minutes and compares real time to target values This will re occur until all values are met 5 Ramps down to Absorption voltage 6 Absorption Charge Regulato...

Страница 8: ...code Indicates temperature setpoint for ambient alternator and battery temperatures Followed by degrees celsius Indicates in millivolts the voltage value used to control voltage compensation for batt...

Страница 9: ...AgL Optima OPS as well as a factory default program UFP and a program for systems with voltage sensitive halogen equipment HAL Programming can be accomplished whenever the regulator is activated Syste...

Страница 10: ...16 and 17 Programming For Secondary Alternator OR Regulator Temperature Sensor The regulator allows the user to select between the use or a second battery temperature sensor or a second alternator tem...

Страница 11: ...ues for that mode will begin to scroll in the opposite direction Continue to HOLD until the desired value is displayed 4 REMOVE the magnet from the RED dot The mode indicator will be displayed again f...

Страница 12: ...indicated Field Threshold Bulk To Absorption Controls the criteria the regulator uses to determine how hard the alternator has to be working to stay in calculated bulk charging mode Factory set at 67...

Страница 13: ...at s capable of providing a signal to a user supplied and installed audible or visual alert to indicate the following while the regulator is in operation Small Engine Mode is activated Regulator is at...

Страница 14: ...tery Sense wire and there is zero or an unexpected voltage reading at the BLUE wire contact our technical support staff at 360 435 6100 or e mail us at balmar balmar net If all voltages at the regulat...

Страница 15: ...tery side of the isolator if an isolator is in use Use a SHIELDED alligator clip for post attachment Unintentional contact between the alligator clip and the alternator case could result in damage to...

Страница 16: ...eplacement In order to expedite warranty claims more efficiently BALMAR asks that prior to returning a defective product for repair you call their customer service department for a warranty return aut...

Отзывы: