www.balluff.com
9
english
4.1
Installing the transducer
NOTICE!
Improper installation
Improper installation can compromise the function of the
transducer and result in damage.
►
For this reason, ensure that no strong electrical or
magnetic fields are present in the immediate vicinity
of the transducer.
►
The recommended spacing for the installation must
be strictly observed.
Any orientation is permitted. Mount the transducer on a
level surface of the machine using the provided mounting
clamps and cylinder-head screws. A sufficient number of
mounting clamps is supplied.
In order to avoid the development of resonant
frequences from vibration loads, we
recommend arranging the mounting clamps at
irregular intervals.
The transducer is electrically isolated from the machine
with the supplied insulating bushes (see Fig. 3-1).
1.
Guide the transducer into the mounting clamps.
2.
Attach transducer to the base using mounting screws
(tighten screws in the clamps with a max. 2 Nm).
3.
Insert magnet (accessories).
The micropulse transducer in profile housing is
suitable both for floating, i.e. non-contacting
magnets (see Fig. 4-4 to Fig. 4-8) and for
captive magnets (see Fig. 4-1 to Fig. 4-3).
4.2
Captive magnets
The following must be observed when installing the
magnet:
– Avoid lateral forces.
– Connect the magnet to the machine member with a
joint rod (see Accessories on page 18).
Fig. 4-1:
66.4
60
1
Dimensions and distances with BTL5-F-2814-1S magnet
Fig. 4-2:
52.5
47.5
1
Dimensions and distances with BTL5-T-2814-1S magnet
Fig. 4-3:
Y
X
1
Dimensions and distances with BTL5-M/N-2814-1S magnet
BTL5-M-2814-1S BTL5-N-2814-1S
Distance X
48.5 mm
57 mm
Distance Y
51 mm
59.5 mm
Tab. 4-1: Distances with BTL5-M/N-2814-1S magnet