1.19 Appendix A. Specific Camera / Sensor Data
181
1.19.1.2.4
Reprogramming CCD Timing
Reprogramming the CCD Controller will happen when the following changes occur
• Changing the exposure time
• Changing the capture window
• Changing Trigger Modes
Reprogram time consists of two phases
1. Time needed to send data to the CCD controller depending on what is changed
exposure : abt 2..3ms
window: abt 4..6ms
trigger mode: from 5..90ms,
varies with oldmode/newmode combination
2. Time to initialize (erase) the CCD chip after reprogramming this is fixed, abt 4.5 ms
So for example when reprogramming the capture window you will need (average values)
t
regprog
= change_ init_ccd
t
regprog
= 5ms + 4.5ms
t
regprog
= 9.5ms
1.19.1.2.5
CCD Sensor Data
Device Structure
• Interline CCD image sensor
• Image size: Diagonal 6mm (Type 1/3)
• Number of effective pixels: 659 (H) x 494 (V) approx. 330K pixels
• Total number of pixels: 692 (H) x 504 (V) approx. 350K pixels
• Chip size: 5.79mm (H) x 4.89mm (V)
• Unit cell size: 7.4um (H) x 7.4um (V)
• Optical black:
–
Horizontal (H) direction: Front 2 pixels, rear 31 pixels
–
Vertical (V) direction: Front 8 pixels, rear 2 pixels
• Number of dummy bits: Horizontal 16 Vertical 5
• Substrate material: Silicon
MATRIX VISION GmbH
Содержание MATRIX VISION mvBlueFOX Series
Страница 1: ...mvBlueFOX Technical Manual English Version 3 02...
Страница 2: ......
Страница 8: ......
Страница 19: ...1 6 Important Information 11 MATRIX VISION GmbH...
Страница 20: ...12 MATRIX VISION GmbH...
Страница 21: ...1 6 Important Information 13 1 6 3 Legal notice 1 6 3 1 For customers in the U S A Class B MATRIX VISION GmbH...
Страница 238: ...230 MATRIX VISION GmbH...