Balluff IO-Link BIS M-4A3-082-401-07-S4 Скачать руководство пользователя страница 4

1

english

The CE Mark verifies that our products meet 

the requirements of the current EU Directive.

BIS M-4A_-082-401-07-S4

Industrial RFID System – Read/Write Head

About this guide

This guide provides important information for installing and 

connecting the BIS M-4A_ HF RFID read/write head with 

IO-Link interface.

It applies to the following models:
–  BIS M-4A3-082-401-07-S4

–  BIS M-4A6-082-401-07-S4

 

– BIS M-4A7-082-401-07-S4

Other applicable documents

A comprehensive user’s guide and additional information 

about this product can be found at 

www.balluff.com

 on 

the product page.

Intended use

The HF RFID read/write head with IO-Link interface forms 

an identification system together with a machine controller 

(e.g. PLC) and an IO-Link master. It is intended to be 

installed into a machine or system and used in the 

industrial sector. 
Flawless function in accordance with the specifications in 

the technical data is ensured only when using suitable 

original Balluff accessories. Use of any other components 

will void the warranty.
Non-approved use is not permitted and will result in the 

loss of warranty and liability claims against the 

manufacturer.

Reasonably foreseeable misuse

The product is not intended for the following applications 

and areas and may not be used there:
–  In safety-oriented applications in which personal safety 

depends on the device function

–  In explosive atmospheres

 

– In direct contact with food

Safety notes

Activities such as 

installation

connection

 and 

commissioning

 may only be carried out by qualified 

personnel.

Qualified personnel

 are persons whose technical 

training, knowledge and experience as well as knowledge 

of the relevant regulations allow them to assess the work 

assigned to them, recognize possible hazards and take 

appropriate safety measures.
The 

operator

 is responsible for ensuring that local safety 

regulations are observed.

In particular, the operator must take steps to ensure that a 

defect in the product will not result in hazards to persons 

or equipment.
The product must not be opened, modified or changed. In 

case of defects and unrepairable malfunctions of the 

product, it must be taken out of operation and secured 

against unauthorized use.
When determining the mounting position, the minimum 

distance of 20 cm between the antenna (active surface) 

and the workstation must be observed.
The antenna of the read/write head emits high-frequency 

electromagnetic waves. IEC 62369 stipulates that 

personnel must not remain within close range of the 

antenna for long periods (several hours).

Dimensions

 M12x1 

 M12x1 

 44.5 

 53.2 

 65 

LED (4x90°)

      17

≤ 15 Nm

Active surface

IO-Link / Power

 44 

 49.5 

 53.2 

 65 

 M12x1 

 M18x1 

LED (4x90°)

       24

≤ 35 Nm

Active surface

IO-Link / Power

 M30x1,5 

 M12x1 

 44 

 49,5 

 53,2 

 65 

LED (4x90°)

       36

≤ 40 Nm

Active surface

IO-Link / Power

BIS M-4A7-082-401-07-S4

BIS M-4A6-082-401-07-S4

BIS M-4A3-082-401-07-S4

Содержание IO-Link BIS M-4A3-082-401-07-S4

Страница 1: ... 4A3 082 401 07 S4 BIS M 4A6 082 401 07 S4 BIS M 4A7 082 401 07 S4 deutsch Montageanleitung english Assembly instructions français Notice de montage italiano Istruzioni di montaggio polski Instrukcja montażu ...

Страница 2: ...hteten Anwendungen in denen die Personensicherheit von der Gerätefunktion abhängt in explosionsgefährdeten Bereichen in direktem Kontakt mit Lebensmitteln Sicherheitshinweise Tätigkeiten wie Einbau Anschluss und Inbetriebnahme dürfen nur durch geschulte Fachkräfte erfolgen Eine geschulte Fachkraft ist wer aufgrund seiner fachli chen Ausbildung seiner Kenntnisse und Erfahrungen sowie seiner Kenntni...

Страница 3: ...ebszustand und Kommunikation Signal Bedeutung Rot statisch Allgemeiner Fehler Grün wechselnd mit LED aus im Verhält nis 10 1 1 s Periode IO Link Kommunikation ist aktiv Das Gerät ist bereit Grün statisch Das Gerät ist bereit Signale der LED 2 CP CM Indikation Warning Teach Ping sowie Namur Standard siehe Dokument IO Link Konfiguration unter www balluff com auf der Pro duktseite Einbau VORSICHT Hoc...

Страница 4: ...rsonal safety depends on the device function In explosive atmospheres In direct contact with food Safety notes Activities such as installation connection and commissioning may only be carried out by qualified personnel Qualified personnel are persons whose technical training knowledge and experience as well as knowledge of the relevant regulations allow them to assess the work assigned to them rec...

Страница 5: ...te and communication Signal Meaning Red static General error Green alternating with LED off in a ratio of 10 1 1 s period IO Link communication is active The device is ready Green static The device is ready Diagnosis functions are on For signals of LED 2 CP CM indication warning teach ping as well as Namur standard see document IO Link configuration at www balluff com on the product page Installat...

Страница 6: ...la sécurité des personnes dépend de la fonction de l appareil dans des zones explosibles En contact direct avec les produits alimentaires Consignes de sécurité Les activités telles que le montage le raccordement et la mise en service ne doivent être exécutées que par un personnel qualifié Est considéré comme qualifié le personnel qui par sa formation technique ses connaissances et son expérience a...

Страница 7: ...fonctionnement et communication Signal Signification Rouge statique Erreur générale Vert alternant avec LED éteinte selon un rapport 10 1 péri ode de 1 s La communication IO Link est active L appareil est prêt Vert statique L appareil est prêt Pour les signaux de la LED 2 CP CM Indication Avertissement Apprentissage Ping ainsi que la norme Namur voir le document Configuration IO Link sur le site w...

Страница 8: ...le persone dipenda dal funzionamento dell apparecchio in aree a rischio di esplosione a diretto contatto con il cibo Avvertenze di sicurezza Attività quali montaggio collegamento e messa in funzione andranno svolte esclusivamente da personale specializzato e addestrato Per personale specializzato e addestrato si intendono persone che grazie alla propria formazione specialistica alle proprie conosc...

Страница 9: ...nto e comunicazione Segnale Significato Luce rossa fissa Errore generale Luce verde alternata a LED spento in rapporto 10 1 periodo 1 sec Comunicazione IO Link attiva Apparecchio pronto Luce verde fissa Apparecchio pronto Per i segnali del LED 2 CP CM indicazione warning teach ping e standard Namur vedere il documento Configurazione IO Link su www balluff com sulla pagina prodotto Montaggio PRUDEN...

Страница 10: ... których bezpieczeństwo osób zależne jest od działania urządzenia w strefach zagrożonych wybuchem w bezpośrednim kontakcie z żywnością Zasady bezpieczeństwa Czynności takie jak montaż podłączenie oraz uruchomienie mogą być przeprowadzane wyłącznie przez przeszkolony personel o odpowiednich kwalifikacjach Za przeszkolony personel uznawane są osoby które ze względu na swoje wykształcenie zawodowe wi...

Страница 11: ...świecenie w kolorze czerwonym Ogólny błąd Świecenie w kolorze zielonym na zmianę z wyłączeniem LED w stosunku 10 1 okres 1 s Komunikacja IO Link jest aktywna Urządzenie jest gotowe Ciągłe świecenie w kolorze zielonym Urządzenie jest gotowe Sygnały diody LED 2 CP CM wskazanie ostrzeżenie uczenie ping oraz Namur Standard patrz dokument Konfiguracja IO Link pod adresem www balluff com na stronie prod...

Страница 12: ...engshan Rd 8F Building A Yunding International Commercial Plaza 200125 Pudong Shanghai Phone 86 400 820 0016 Fax 86 400 920 2622 service cn balluff com cn DACH Service Center Germany Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Phone 49 7158 173 370 service de balluff de Eastern Europe Service Center Poland Balluff Sp z o o Ul Graniczna 21A 54 516 Wrocław Phone 48 71 382 09 02 service pl ...

Отзывы: