www.balluff.com
25
english
Reset the sensor to its factory default setting using the
system command (0x0002)
Restore Factory Settings
(0x82). By default, the additional functions
Counter func-
tions
are disabled.
For a listing of all parameters that can be set via IO-Link,
IO-Link interface: Parameters, commands and
Parameter
Factory setting
Description
Teach-in Channel
0x00
Manufacturer / vendor specific default (BDC 1)
Switch Point Logic
0x00
High active
Switch point mode
0x01
Single Point Mode
Set Point 1
Variable
Manufacturer calibrated rated switching distance
Set Point 2
0000
Pin Function Selection PIN 4
0x00
Sensor Output
Pin Function Selection PIN 2
0x01
Teach-in Input
Physical Input Debounce PIN 2
0x12C (300)
300 ms debounce time
Output Type PIN 4
0x03
Push-Pull
Output Type PIN 2
0x03
Push-pull (not used, PIN 2 is by default an input.)
Output Function PIN 4
0x00
N.O.
Output Function PIN 2
0x00
N.O. (not used, PIN 2 is by default an input.)
Device Access
0
All functions enabled
Application Specific Tag
„***“
Function Tag
„***“
Location Tag
„***“
Switch Counter Mode
0x00
OFF
Switch Counter Limit
0x0000
OFF
Switch Counter Debounce
0x0000
OFF
Switch Counter Startup Delay
0x0000
OFF
Switch Counter Upper Limit High 0x0000
OFF
Switch Counter Upper Limit Low 0x0000
OFF
Switch Counter Lower Limit High 0x0000
OFF
Switch Counter Lower Limit Low 0x0000
OFF
Tab. 9-1: Factory setting
9
Factory setting
BES M12M_1-YIC_0_-S04G
Inductive sensors